Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-RES-0525-02593
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
10675 E BRIDGEPORT ST
Address NEW:
10675 E BRIDGEPORT ST
Apply Date:
05/15/2025
Applicant:
TFS Solar
Description:
Roof mount 11.31 kW DC photovoltaic solar system; 26 modules. 27 kWh Storage, 2 Tesla Powerwall-3 batteries with integrated PV inverter. (1) 11.5kW with 2 strings, (1) 7.6kW with 2 strings. 125A generation panel to solar meter, 100A OCP. 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup. 14-50 NEMA rated outlet for EV charger with 50A GFCI breaker.
Permit Reviews
Permit Number - TC-RES-0525-02593
Permit Status: Complete
Permit Description: Roof mount 11.31 kW DC photovoltaic solar system; 26 modules. 27 kWh Storage, 2 Tesla Powerwall-3 batteries with integrated PV inverter. (1) 11.5kW with 2 strings, (1) 7.6kW with 2 strings.
125A generation panel to solar meter, 100A OCP.
200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.
14-50 NEMA rated outlet for EV charger with 50A GFCI breaker.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/16/2025 | RESIDENTIAL SOLAR v.1 | 06/12/2025 | APPROVED |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-0525-02593
Permite Description: Roof mount 11.31 kW DC photovoltaic solar system; 26 modules. 27 kWh Storage, 2 Tesla Powerwall-3 batteries with integrated PV inverter. (1) 11.5kW with 2 strings, (1) 7.6kW with 2 strings.
125A generation panel to solar meter, 100A OCP.
200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.
14-50 NEMA rated outlet for EV charger with 50A GFCI breaker.
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/16/2025 | BULD - Electrical Clearance | N/A | Partial Pass | Partial pass. Verbal clearance to TEP DGL. ( Tesla backup switch) 7-16-2025 |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0525-02593
Permit Description: Roof mount 11.31 kW DC photovoltaic solar system; 26 modules. 27 kWh Storage, 2 Tesla Powerwall-3 batteries with integrated PV inverter. (1) 11.5kW with 2 strings, (1) 7.6kW with 2 strings.
125A generation panel to solar meter, 100A OCP.
200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.
14-50 NEMA rated outlet for EV charger with 50A GFCI breaker.
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/21/2025 | BULD - Electrical Clearance | Passed | Approved solar with the PW3 - DGC/BAT Clearance to TEP is required for the solar meter | |
| 07/21/2025 | RSBU - Building Final | Passed | ||
| 07/21/2025 | COT - RSOL - Electrical Final Solar Project | Passed |