Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Apply Date:
05/01/2024
Applicant:
Richard Main
Description:
New Gunite Swimming Pool

Permit Reviews

Permit Number - TC-RES-0524-02653
Permit Status: Inspections complete
Permit Description: New Gunite Swimming Pool
Start Date Submittal Complete Date Status  
05/02/2024 RESIDENTIAL POOL v.1 05/14/2024 REQUIRES RESUBMIT Review Details
05/29/2024 RESIDENTIAL POOL v.2 06/25/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-0524-02653
Permit Status: Inspections complete
Permit Description: New Gunite Swimming Pool
Total Outstanding Activity Conditions - 1
Date Name
06/25/2024 Must Upload City of Tucson Standard Engineering from AMTEC that has been stamped in 2024 prior to issuance of permit.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0524-02653
Permite Description: New Gunite Swimming Pool
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
08/12/2024 Pool/Spa - Electric N/A Partial Pass underground electrical conduit for pool lights is installed to corner of house. no other electrical work has been done.
08/12/2024 RSEL - Electrical Progress N/A Partial Pass underground electrical conduit for pool lights is installed to corner of house. no other electrical work has been done.
08/12/2024 COT - RSEL - Electrical Final N/A Partial Pass underground electrical conduit for pool lights is installed to corner of house. no other electrical work has been done.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0524-02653
Permit Description: New Gunite Swimming Pool
Total Completed Inspections - 9
Date Description Inspector Results Comments
07/26/2024 Pool/Spa - Bonding Grip Passed Grounding wire is ran around pool and connected to wall and floor rebar reinforcement in 5 locations and at the pool pump motor.
07/26/2024 Pool/Spa - Pre-Gunite Passed Grounding wire is installed, rebar reinforcement for walls and pool floor is properly installed and supported 3” off of the dirt, and light fixtures, skimmer basket, water jets, and pool cleaning pipes are properly installed. Okay to proceed with gunite application.
07/26/2024 Pool/Spa - Plumbing Passed Pool underground plumbing pipes are installed in trench, need to remove all large rocks on top and in between pool plumbing pipes prior to shading and backfilling trenches.
08/12/2024 COT - BULD - SWG Clearance Passed Gas line is installed from meter to pool heater and under 15 psi of air pressure. Okay to backfill gas line trench. SWG Clearance issued to Southwest Gas Company.
10/02/2024 Pool/Spa - Electric Passed pool electrical control box and GFCI receptacle are complete
10/02/2024 RSBU - Building Final Passed Pool construction is complete. Okay to pebble tech and fill pool with water.
10/02/2024 RSEL - Electrical Progress Passed complete
10/02/2024 COT - RSEL - Electrical Final Passed 10/2/24: Electrical for pool lights and equipment is installed.
10/02/2024 Pool/Spa - Final/Barrier Passed door alarms are installed and gates is self closing and latching.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-OLSON POOL_SITE PLAN_240528 (1)_V2.PDF DOCUMENTS VIEW
OLSON POOL_SITE PLAN_240528_V1.PDF DOCUMENTS VIEW