Permit: TC-RES-0426-02092
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
8543 E 24TH ST
Address NEW:
8543 E 24TH ST
Apply Date:
04/23/2026
Applicant:
Breanna Andree-Couturier
Description:
Replacement of existing 3" cast iron sewer main line under residential structure using pipe bursting method. Work includes saw cutting and removal of concrete in bathroom, interior and exterior excavation to access existing sewer mainline, and bursting of sewer line from bathroom to exterior of property (up to 50 linear feet). New sewer line to be installed using SDR 17 and Schedule 40 ABS pipe and fittings. Pipes to be rebared and salt treated upon installation. Dual sweep cleanouts to be installed at exterior of structure per code. All work to be backfilled, compacted, and concrete restored to rough grade. All plumbing to be performed in accordance with International Plumbing Code.
Permit Reviews
Permit Number - TC-RES-0426-02092
Permit Status: Complete
Permit Description: Replacement of existing 3" cast iron sewer main line under residential structure using pipe bursting method. Work includes saw cutting and removal of concrete in bathroom, interior and exterior excavation to access existing sewer mainline, and bursting of sewer line from bathroom to exterior of property (up to 50 linear feet). New sewer line to be installed using SDR 17 and Schedule 40 ABS pipe and fittings. Pipes to be rebared and salt treated upon installation. Dual sweep cleanouts to be installed at exterior of structure per code. All work to be backfilled, compacted, and concrete restored to rough grade. All plumbing to be performed in accordance with International Plumbing Code.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/14/2026 | RESIDENTIAL SIMPLE REVIEW v.2 | N/A | APPROVED |
| 04/23/2026 | RESIDENTIAL SIMPLE REVIEW v.1 | 04/23/2026 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-0426-02092
Permit Status: Complete
Permit Description: Replacement of existing 3" cast iron sewer main line under residential structure using pipe bursting method. Work includes saw cutting and removal of concrete in bathroom, interior and exterior excavation to access existing sewer mainline, and bursting of sewer line from bathroom to exterior of property (up to 50 linear feet). New sewer line to be installed using SDR 17 and Schedule 40 ABS pipe and fittings. Pipes to be rebared and salt treated upon installation. Dual sweep cleanouts to be installed at exterior of structure per code. All work to be backfilled, compacted, and concrete restored to rough grade. All plumbing to be performed in accordance with International Plumbing Code.
| Date | Description | Comments |
|---|---|---|
| 04/23/2026 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0426-02092
Permit Description: Replacement of existing 3" cast iron sewer main line under residential structure using pipe bursting method. Work includes saw cutting and removal of concrete in bathroom, interior and exterior excavation to access existing sewer mainline, and bursting of sewer line from bathroom to exterior of property (up to 50 linear feet). New sewer line to be installed using SDR 17 and Schedule 40 ABS pipe and fittings. Pipes to be rebared and salt treated upon installation. Dual sweep cleanouts to be installed at exterior of structure per code. All work to be backfilled, compacted, and concrete restored to rough grade. All plumbing to be performed in accordance with International Plumbing Code.
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/15/2026 | COT - RSPL - Rough Soil | Passed | Passed | |
| 06/15/2026 | COT - RSPL - Sewer | Passed | Passed | |
| 09/23/2026 | RSBU - Building Final | Passed | 09/23/2026 Verified all appliances installed and holding under test. |
|
| 09/23/2026 | COT - RSPL - Plumbing Final | Passed | 09/23/2026 Verified all appliances installed and holding under test. |