Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address:
8543 E 24TH ST
Address NEW:
8543 E 24TH ST
Apply Date:
04/23/2026
Applicant:
Breanna Andree-Couturier
Description:
Replacement of existing 3" cast iron sewer main line under residential structure using pipe bursting method. Work includes saw cutting and removal of concrete in bathroom, interior and exterior excavation to access existing sewer mainline, and bursting of sewer line from bathroom to exterior of property (up to 50 linear feet). New sewer line to be installed using SDR 17 and Schedule 40 ABS pipe and fittings. Pipes to be rebared and salt treated upon installation. Dual sweep cleanouts to be installed at exterior of structure per code. All work to be backfilled, compacted, and concrete restored to rough grade. All plumbing to be performed in accordance with International Plumbing Code.

Permit Reviews

Permit Number - TC-RES-0426-02092
Permit Status: Complete
Permit Description: Replacement of existing 3" cast iron sewer main line under residential structure using pipe bursting method. Work includes saw cutting and removal of concrete in bathroom, interior and exterior excavation to access existing sewer mainline, and bursting of sewer line from bathroom to exterior of property (up to 50 linear feet). New sewer line to be installed using SDR 17 and Schedule 40 ABS pipe and fittings. Pipes to be rebared and salt treated upon installation. Dual sweep cleanouts to be installed at exterior of structure per code. All work to be backfilled, compacted, and concrete restored to rough grade. All plumbing to be performed in accordance with International Plumbing Code.
Start Date Submittal Complete Date Status  
05/14/2026 RESIDENTIAL SIMPLE REVIEW v.2 N/A APPROVED Review Details
04/23/2026 RESIDENTIAL SIMPLE REVIEW v.1 04/23/2026 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-RES-0426-02092
Permit Status: Complete
Permit Description: Replacement of existing 3" cast iron sewer main line under residential structure using pipe bursting method. Work includes saw cutting and removal of concrete in bathroom, interior and exterior excavation to access existing sewer mainline, and bursting of sewer line from bathroom to exterior of property (up to 50 linear feet). New sewer line to be installed using SDR 17 and Schedule 40 ABS pipe and fittings. Pipes to be rebared and salt treated upon installation. Dual sweep cleanouts to be installed at exterior of structure per code. All work to be backfilled, compacted, and concrete restored to rough grade. All plumbing to be performed in accordance with International Plumbing Code.
Date Description Comments
04/23/2026 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0426-02092
Permit Description: Replacement of existing 3" cast iron sewer main line under residential structure using pipe bursting method. Work includes saw cutting and removal of concrete in bathroom, interior and exterior excavation to access existing sewer mainline, and bursting of sewer line from bathroom to exterior of property (up to 50 linear feet). New sewer line to be installed using SDR 17 and Schedule 40 ABS pipe and fittings. Pipes to be rebared and salt treated upon installation. Dual sweep cleanouts to be installed at exterior of structure per code. All work to be backfilled, compacted, and concrete restored to rough grade. All plumbing to be performed in accordance with International Plumbing Code.
Total Completed Inspections - 4
Date Description Inspector Results Comments
06/15/2026 COT - RSPL - Rough Soil Passed Passed
06/15/2026 COT - RSPL - Sewer Passed Passed
09/23/2026 RSBU - Building Final Passed 09/23/2026
Verified all appliances installed and holding under test.
09/23/2026 COT - RSPL - Plumbing Final Passed 09/23/2026
Verified all appliances installed and holding under test.