Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Apply Date:
04/07/2026
Applicant:
Jai Walker
Description:
WHOLE HOME GAS RE-PIPE START AT METER THERE IS A TEE AT METER THAT FEEDS TANKLESS IN 3/4. FROM TEE WILL UPGRAGE PIPE TO 1 1/4 AND SURFACE MOUT ON EXTERIOR WALL GOING UP 5 FEET AND ADDING ANOTHER TEE FOR FURNACE THAT GOES TO EXTERIOR CLOSET AND WELL STUB IN 3 FEET. AFTER TEE LINE GOES ON ROOF AND WILL REDUCE TO 3/4 AND RUN 25 FEET AND STUB DOWN 9 FEET TO FEED RANGE. WITH A TOTAL OF 52 FEET. PIPE MATERIAL WILL BE BLACK IRON. ALL PIPING WILL BE PROPERLY STRAPPED. AND TOTAL BTUS DEMAND IS 295,000

Permit Reviews

Permit Number - TC-RES-0426-01713
Permit Status: Complete
Permit Description: WHOLE HOME GAS RE-PIPE START AT METER THERE IS A TEE AT METER THAT FEEDS TANKLESS IN 3/4. FROM TEE WILL UPGRAGE PIPE TO 1 1/4 AND SURFACE MOUT ON EXTERIOR WALL GOING UP 5 FEET AND ADDING ANOTHER TEE FOR FURNACE THAT GOES TO EXTERIOR CLOSET AND WELL STUB IN 3 FEET. AFTER TEE LINE GOES ON ROOF AND WILL REDUCE TO 3/4 AND RUN 25 FEET AND STUB DOWN 9 FEET TO FEED RANGE. WITH A TOTAL OF 52 FEET. PIPE MATERIAL WILL BE BLACK IRON. ALL PIPING WILL BE PROPERLY STRAPPED. AND TOTAL BTUS DEMAND IS 295,000
Start Date Submittal Complete Date Status  
04/07/2026 RESIDENTIAL SIMPLE REVIEW v.1 04/08/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-0426-01713
Permit Status: Complete
Permit Description: WHOLE HOME GAS RE-PIPE START AT METER THERE IS A TEE AT METER THAT FEEDS TANKLESS IN 3/4. FROM TEE WILL UPGRAGE PIPE TO 1 1/4 AND SURFACE MOUT ON EXTERIOR WALL GOING UP 5 FEET AND ADDING ANOTHER TEE FOR FURNACE THAT GOES TO EXTERIOR CLOSET AND WELL STUB IN 3 FEET. AFTER TEE LINE GOES ON ROOF AND WILL REDUCE TO 3/4 AND RUN 25 FEET AND STUB DOWN 9 FEET TO FEED RANGE. WITH A TOTAL OF 52 FEET. PIPE MATERIAL WILL BE BLACK IRON. ALL PIPING WILL BE PROPERLY STRAPPED. AND TOTAL BTUS DEMAND IS 295,000
Date Description Comments
04/07/2026 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0426-01713
Permit Description: WHOLE HOME GAS RE-PIPE START AT METER THERE IS A TEE AT METER THAT FEEDS TANKLESS IN 3/4. FROM TEE WILL UPGRAGE PIPE TO 1 1/4 AND SURFACE MOUT ON EXTERIOR WALL GOING UP 5 FEET AND ADDING ANOTHER TEE FOR FURNACE THAT GOES TO EXTERIOR CLOSET AND WELL STUB IN 3 FEET. AFTER TEE LINE GOES ON ROOF AND WILL REDUCE TO 3/4 AND RUN 25 FEET AND STUB DOWN 9 FEET TO FEED RANGE. WITH A TOTAL OF 52 FEET. PIPE MATERIAL WILL BE BLACK IRON. ALL PIPING WILL BE PROPERLY STRAPPED. AND TOTAL BTUS DEMAND IS 295,000
Total Completed Inspections - 2
Date Description Inspector Results Comments
04/20/2026 COT - BULD - SWG Clearance Passed 4/20/26
Southwest gas: SWG, called in at 9:50 am.
04/20/2026 COT - RSPL - Plumbing Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-GAS PIPING_V1.PDF DOCUMENTS VIEW
PROPERTY PLAN_V1.PDF DOCUMENTS VIEW