Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Address:
2716 E 7TH ST
Address NEW:
2716 E 7TH ST
Apply Date:
04/15/2025
Applicant:
Stephen Jobe
Description:
Scope of work to replace gas line on property starting from meter throughout home as follows: -disconnected and removed all existing black iron piping from areas where it is accessible -drilled new holes in floor where new pipe will go through - ran all new 1”, 3/4” and 1/2 black iron pipe - installed all new fittings and made proper connections - installed all new 1/2” and 3/4” gas valves for a total of 2 valves - properly strapped black iron pipe in crawl space - ran 1" black iron pipe along outside side wall, secured it using unistraps and proper clamps. - continued to run 1" pipe on the roof for another 15' and reduced to 3/4" black iron pipe - ran 3/4" pipe from roof down into inside the home towards the furnace for approx 18' - supported roof pipe with 4x4 wood and proper straps - checked all connections - upon completion of install, we performed a 15 pound gas pressure test for 30 minutes to ensure proper hold of pressure. It passed. We will left line pressurized with air to finalize permitting process and schedule inspections. Upon completion of inspections Southwest gas will re-hook up gas meter to system.

Permit Reviews

Permit Number - TC-RES-0425-01989
Permit Status: Issued
Permit Description: Scope of work to replace gas line on property starting from meter throughout home as follows: -disconnected and removed all existing black iron piping from areas where it is accessible -drilled new holes in floor where new pipe will go through - ran all new 1”, 3/4” and 1/2 black iron pipe - installed all new fittings and made proper connections - installed all new 1/2” and 3/4” gas valves for a total of 2 valves - properly strapped black iron pipe in crawl space - ran 1" black iron pipe along outside side wall, secured it using unistraps and proper clamps. - continued to run 1" pipe on the roof for another 15' and reduced to 3/4" black iron pipe - ran 3/4" pipe from roof down into inside the home towards the furnace for approx 18' - supported roof pipe with 4x4 wood and proper straps - checked all connections - upon completion of install, we performed a 15 pound gas pressure test for 30 minutes to ensure proper hold of pressure. It passed. We will left line pressurized with air to finalize permitting process and schedule inspections. Upon completion of inspections Southwest gas will re-hook up gas meter to system.
Start Date Submittal Complete Date Status  
04/15/2025 RESIDENTIAL SIMPLE REVIEW v.1 04/16/2025 APPROVED Review Details

Conditions

Permit Number - TC-RES-0425-01989
Permit Status: Issued
Permit Description: Scope of work to replace gas line on property starting from meter throughout home as follows: -disconnected and removed all existing black iron piping from areas where it is accessible -drilled new holes in floor where new pipe will go through - ran all new 1”, 3/4” and 1/2 black iron pipe - installed all new fittings and made proper connections - installed all new 1/2” and 3/4” gas valves for a total of 2 valves - properly strapped black iron pipe in crawl space - ran 1" black iron pipe along outside side wall, secured it using unistraps and proper clamps. - continued to run 1" pipe on the roof for another 15' and reduced to 3/4" black iron pipe - ran 3/4" pipe from roof down into inside the home towards the furnace for approx 18' - supported roof pipe with 4x4 wood and proper straps - checked all connections - upon completion of install, we performed a 15 pound gas pressure test for 30 minutes to ensure proper hold of pressure. It passed. We will left line pressurized with air to finalize permitting process and schedule inspections. Upon completion of inspections Southwest gas will re-hook up gas meter to system.
Date Description Comments
04/15/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
2716_V1.PDF DOCUMENTS VIEW