Install a 110 volts GFCI outlet 20 ams breaker for outdoor kitchen from breakers panel. Install 88' long of #12 uf wire in a schedule 40 conduit 18" deep and sch80 conduit above ground. Install 85' of 3/4" yellow poly gas line with tracer wire for outdoor grill BTUH=92100 Gas line to be buried 20"-24".

Permit Reviews

Permit Number - TC-RES-0424-02308
Permit Status: Complete
Permit Description: Install a 110 volts GFCI outlet 20 ams breaker for outdoor kitchen from breakers panel. Install 88' long of #12 uf wire in a schedule 40 conduit 18" deep and sch80 conduit above ground. Install 85' of 3/4" yellow poly gas line with tracer wire for outdoor grill BTUH=92100 Gas line to be buried 20"-24".
Start Date Submittal Complete Date Status  
04/18/2024 RESIDENTIAL SIMPLE REVIEW v.2 04/18/2024 APPROVED Review Details
04/18/2024 RESIDENTIAL SIMPLE REVIEW v.1 04/18/2024 REQUIRES RESUBMIT Review Details

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0424-02308
Permit Description: Install a 110 volts GFCI outlet 20 ams breaker for outdoor kitchen from breakers panel. Install 88' long of #12 uf wire in a schedule 40 conduit 18" deep and sch80 conduit above ground. Install 85' of 3/4" yellow poly gas line with tracer wire for outdoor grill BTUH=92100 Gas line to be buried 20"-24".
Total Completed Inspections - 5
Date Description Inspector Results Comments
06/24/2024 COT - RSEL - Electrical Underground Passed 6/24/24: (1) 3/4" conduit from main panel to new receptacle at bbq grill ok to backfill,
07/22/2024 COT - BULD - SWG Clearance Passed 7/22/24: SWG Clearance
07/26/2024 RSPL - Plumbing Progress Passed
07/26/2024 COT - RSEL - Electrical Final Passed Project complete.
CLOSE PERMIT
07/26/2024 COT - RSPL - Plumbing Final Passed Project complete.
CLOSE PERMIT