Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Apply Date:
03/09/2026
Applicant:
Jesus Galaz
Description:
HVAC & Electrical Scope of Work – HVAC System Replacement Proposed Equipment: Outdoor Unit Model #: GZV7SA4810A Indoor Unit Model #: AHVE60DP1300A AHRI Certified #: 215429199 Energy Star Unique #: 3625030 Installation Includes: Installation of new thermostat New supply duct connections routed through the garage as needed Installation of a filter base for easier and cleaner filter replacements Connect condensate drain line to existing approved drain location Connect outdoor unit to existing high-voltage power at condenser location (if usable) Flush refrigerant lines using R-11 Flush and nitrogen to ensure a clean system start-up Install a surge protector to help protect the system from power spikes Removal and proper disposal of existing HVAC equipment Complete installation, start-up, and system testing to ensure proper operation Run high voltage from main Install surge protector Install new breaker in main panel

Permit Reviews

Permit Number - TC-RES-0326-01199
Permit Status: Issued
Permit Description: HVAC & Electrical Scope of Work – HVAC System Replacement Proposed Equipment: Outdoor Unit Model #: GZV7SA4810A Indoor Unit Model #: AHVE60DP1300A AHRI Certified #: 215429199 Energy Star Unique #: 3625030 Installation Includes: Installation of new thermostat New supply duct connections routed through the garage as needed Installation of a filter base for easier and cleaner filter replacements Connect condensate drain line to existing approved drain location Connect outdoor unit to existing high-voltage power at condenser location (if usable) Flush refrigerant lines using R-11 Flush and nitrogen to ensure a clean system start-up Install a surge protector to help protect the system from power spikes Removal and proper disposal of existing HVAC equipment Complete installation, start-up, and system testing to ensure proper operation Run high voltage from main Install surge protector Install new breaker in main panel
Start Date Submittal Complete Date Status  
03/09/2026 RESIDENTIAL SIMPLE REVIEW v.1 03/09/2026 REQUIRES RESUBMIT Review Details
03/09/2026 RESIDENTIAL SIMPLE REVIEW v.2 03/10/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-0326-01199
Permit Status: Issued
Permit Description: HVAC & Electrical Scope of Work – HVAC System Replacement Proposed Equipment: Outdoor Unit Model #: GZV7SA4810A Indoor Unit Model #: AHVE60DP1300A AHRI Certified #: 215429199 Energy Star Unique #: 3625030 Installation Includes: Installation of new thermostat New supply duct connections routed through the garage as needed Installation of a filter base for easier and cleaner filter replacements Connect condensate drain line to existing approved drain location Connect outdoor unit to existing high-voltage power at condenser location (if usable) Flush refrigerant lines using R-11 Flush and nitrogen to ensure a clean system start-up Install a surge protector to help protect the system from power spikes Removal and proper disposal of existing HVAC equipment Complete installation, start-up, and system testing to ensure proper operation Run high voltage from main Install surge protector Install new breaker in main panel
Date Description Comments
03/09/2026 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-IMG_1863_V1 (2)_V1.PDF DOCUMENTS VIEW
HVAC_MECHANICAL_SPECIFICATIONS_GZV7SA4810A_AHVE60DP1300A_V1.PDF DOCUMENTS VIEW