Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address NEW:
9401 E LURLENE DR
Apply Date:
03/03/2026
Applicant:
Jai Walker
Description:
REAPLACING GAS MAIN FROM METER TO HOME. LINE WILL RUN FROM METER TO THE SIDE OF HOME 52 FEET UNDERGROUND WITH A DEPTH OF 18 INCHES, AND WILL HAVE 18 GUAGE AWG YELLOW TRACER WIRE. THEN LINE WILL GO UP TO ROOF AND ACROSS TO MIDDLE OF HOME 48 FEET AND WILL THEN GO DOWN 8 FEET TO WERE LINE GOES INTO HOME. TOTAL LENGHT OF PIPE IS 108 FEET, AND WILL FEED 3 FIXTURES WATER HEATER, FURNACE AND BARBQUE WITH A TOTAL OF 180,000 BTUS. ALL PIPE WILL BE RAN IN 1 INCH. (MATERIAL) UNDERGROUND PIPE WILL BE (PE POLYETHELNE) EXPOSED PIPE WILL BE BLACK IORN ALL PIPE WILL BE STRAPPED AND SECURED, AND TESTED

Permit Reviews

Permit Number - TC-RES-0326-01081
Permit Status: Complete
Permit Description: REAPLACING GAS MAIN FROM METER TO HOME. LINE WILL RUN FROM METER TO THE SIDE OF HOME 52 FEET UNDERGROUND WITH A DEPTH OF 18 INCHES, AND WILL HAVE 18 GUAGE AWG YELLOW TRACER WIRE. THEN LINE WILL GO UP TO ROOF AND ACROSS TO MIDDLE OF HOME 48 FEET AND WILL THEN GO DOWN 8 FEET TO WERE LINE GOES INTO HOME. TOTAL LENGHT OF PIPE IS 108 FEET, AND WILL FEED 3 FIXTURES WATER HEATER, FURNACE AND BARBQUE WITH A TOTAL OF 180,000 BTUS. ALL PIPE WILL BE RAN IN 1 INCH. (MATERIAL) UNDERGROUND PIPE WILL BE (PE POLYETHELNE) EXPOSED PIPE WILL BE BLACK IORN ALL PIPE WILL BE STRAPPED AND SECURED, AND TESTED
Start Date Submittal Complete Date Status  
03/03/2026 RESIDENTIAL SIMPLE REVIEW v.1 03/03/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-0326-01081
Permit Status: Complete
Permit Description: REAPLACING GAS MAIN FROM METER TO HOME. LINE WILL RUN FROM METER TO THE SIDE OF HOME 52 FEET UNDERGROUND WITH A DEPTH OF 18 INCHES, AND WILL HAVE 18 GUAGE AWG YELLOW TRACER WIRE. THEN LINE WILL GO UP TO ROOF AND ACROSS TO MIDDLE OF HOME 48 FEET AND WILL THEN GO DOWN 8 FEET TO WERE LINE GOES INTO HOME. TOTAL LENGHT OF PIPE IS 108 FEET, AND WILL FEED 3 FIXTURES WATER HEATER, FURNACE AND BARBQUE WITH A TOTAL OF 180,000 BTUS. ALL PIPE WILL BE RAN IN 1 INCH. (MATERIAL) UNDERGROUND PIPE WILL BE (PE POLYETHELNE) EXPOSED PIPE WILL BE BLACK IORN ALL PIPE WILL BE STRAPPED AND SECURED, AND TESTED
Date Description Comments
03/03/2026 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0326-01081
Permit Description: REAPLACING GAS MAIN FROM METER TO HOME. LINE WILL RUN FROM METER TO THE SIDE OF HOME 52 FEET UNDERGROUND WITH A DEPTH OF 18 INCHES, AND WILL HAVE 18 GUAGE AWG YELLOW TRACER WIRE. THEN LINE WILL GO UP TO ROOF AND ACROSS TO MIDDLE OF HOME 48 FEET AND WILL THEN GO DOWN 8 FEET TO WERE LINE GOES INTO HOME. TOTAL LENGHT OF PIPE IS 108 FEET, AND WILL FEED 3 FIXTURES WATER HEATER, FURNACE AND BARBQUE WITH A TOTAL OF 180,000 BTUS. ALL PIPE WILL BE RAN IN 1 INCH. (MATERIAL) UNDERGROUND PIPE WILL BE (PE POLYETHELNE) EXPOSED PIPE WILL BE BLACK IORN ALL PIPE WILL BE STRAPPED AND SECURED, AND TESTED
Total Completed Inspections - 3
Date Description Inspector Results Comments
03/12/2026 COT - BULD - SWG Clearance Passed PASSED 3/12/26 CLEARANCE SWG
03/12/2026 COT - RSPL - Plumbing Final Passed PASSED 3/12/26 CLEARANCE SWG
03/12/2026 RSBU - Building Final Passed PASSED 3/12/26 CLEARANCE SWG

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-MATTHEW COAK GAS DRAWING_V1.PDF DOCUMENTS VIEW
MATTHEW COAK PROPERTY DRAWING_V1.PDF DOCUMENTS VIEW