Permit: TC-RES-0324-01244
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
12746 E MEAGAN RIDGE PL
Address NEW:
12746 E MEAGAN RIDGE PL
Apply Date:
03/02/2024
Applicant:
Description:
Side Retaining Wall 100' Long @ 3' Tall with 5' wall
Permit Reviews
Permit Number - TC-RES-0324-01244
Permit Status: Complete
Permit Description: Side Retaining Wall 100' Long @ 3' Tall with 5' wall
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/05/2024 | RESIDENTIAL FENCE/WALL v.1 | 03/19/2024 | REQUIRES RESUBMIT |
| 03/20/2024 | RESIDENTIAL FENCE/WALL v.2 | 04/04/2024 | APPROVED |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-0324-01244
Permite Description: Side Retaining Wall 100' Long @ 3' Tall with 5' wall
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/05/2024 | COT - RSBU - Stem Wall/Retaining Wall | N/A | Partial Pass | Retaining Wall grouted. Ready for screen wall installation. |
| 06/24/2024 | RSBU - Building Final | N/A | Partial Pass | Lot north retaining wall and footer have been completed, but the screen wall has not been constructed yet. The south and west common walls with the adjacent lots have been fully completed. The Screen wall on top of the retaining wall is all that has not been completed at this time. T contractor will reschedule the final Inspection once the screen wall is complete. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0324-01244
Permit Description: Side Retaining Wall 100' Long @ 3' Tall with 5' wall
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/02/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | The east and west wall footers are Approved at this time. The rebar is as shown on the Approved plans but is only approximately 3 inches above the trench bottom, have advised MJM Construction that the rebar should have 4 to 6 inches of clearance to allow for proper concrete placement. | |
| 06/05/2024 | COT - RSBU - Masonry Pregrout | Passed | Reinforcing steel in place. Ready to grout retaining wall. | |
| 01/16/2025 | COT - RSBU - Stem Wall/Retaining Wall | Passed | ||
| 01/16/2025 | RSBU - Building Final | Passed |