Permit Reviews

Permit Number - TC-RES-0323-03782
Permit Status: Complete
Permit Description: Remodel SFR and Family Room Addition
Start Date Submittal Complete Date Status  
05/17/2023 RESIDENTIAL NEW DWELLING v.2 05/18/2023 APPROVED Review Details
03/23/2023 RESIDENTIAL NEW DWELLING v.1 04/20/2023 REQUIRES RESUBMIT Review Details
05/18/2023 RESTAMP - RESIDENTIAL v.1 05/18/2023 APPROVED Review Details

Conditions

Permit Number - TC-RES-0323-03782
Permit Status: Complete
Permit Description: Remodel SFR and Family Room Addition
Date Description Comments
05/18/2023 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/integrated-planning/PDSD/PDSD_Owner_Builder_Affidavit.pdf, is required prior to issuance of permit.
04/13/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0323-03782
Permite Description: Remodel SFR and Family Room Addition
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
09/06/2023 COT - RSEL - Outdoor Lighting N/A Re-inspection required 9/6/23: call in for final inspection, exterior outlets required to be WR, add 2 outlets at kitchen counter area, water heater over-flow required to terminate to exterior.
09/14/2023 COT - RSEL - Electrical Final N/A Partial Pass Partial pending gfci at dishwasher and laundry room. 9/14/2023
09/22/2023 RSBU - Building Final N/A Partial Pass Partial pending gfci at dishwasher and laundry room. 9/14/2023

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0323-03782
Permit Description: Remodel SFR and Family Room Addition
Total Completed Inspections - 14
Date Description Inspector Results Comments
06/06/2023 COT - RSPL - Rough Soil Passed 6/6/23: rough soil passed
06/08/2023 COT - RSBU - Excavation/Rebar/Zoning Passed Rebar per plans. Okay for concrete placement. 6/8/2023
06/08/2023 COT - RSBU - Preslab Passed Rebar per plans. Okay for concrete placement. 6/8/2023
06/08/2023 COT - RSEL - Grounding/Bonding Passed
06/27/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
06/27/2023 COT - RSBU - Roof Nailing Passed
07/12/2023 BULD - Electrical Clearance Passed Electrical rough-in complete. Electrical panel is properly installed. ECO Clearance issued. Okay to energize.
07/12/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Mechanical, electrical, and plumbing rough-in is complete. Okay to insulate, drywall, tape, and texture walls.
07/12/2023 COT - RSPL - Yard Water Line Passed Yard water line is connected from meter to house.
09/13/2023 COT - RSME - Mechanical Final Passed
09/13/2023 COT - RSEL - Outdoor Lighting Passed Corrections were made. 9/13/2023
09/13/2023 COT - RSPL - Plumbing Final Passed
09/18/2023 COT - RSEL - Electrical Final Passed Approved electric, SFR is complete
09/20/2023 RSBU - Building Final Passed 9/20/23: Contractor has installed GFCI outlets under sink for dishwasher and in laundry room.