Permit: TC-RES-0323-03356
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
2210 S FORGEUS AV
Address NEW:
2210 S FORGEUS AV
Apply Date:
03/07/2023
Applicant:
BRANDY PALCHETTI
Description:
• SYSTEM SIZE: 10540W DC, 7440W AC • MODULES: (31) JA SOLAR: JAM60S10-340/MR • INVERTERS: (31) ENPHASE ENERGY: IQ7-60-2-US • RACKING: ULTRA RAIL, ATTACHMENT DETAIL, OMNIBASE WITH STANDOFF TO RAFTER: SNR-DC-01249; SOLLEGA FASTRACK510 WITH 304 STAINLESS STEEL HARDWARE
Permit Reviews
Permit Number - TC-RES-0323-03356
Permit Status: Issued
Permit Description: • SYSTEM SIZE: 10540W DC, 7440W AC
• MODULES: (31) JA SOLAR: JAM60S10-340/MR
• INVERTERS: (31) ENPHASE ENERGY: IQ7-60-2-US
• RACKING: ULTRA RAIL, ATTACHMENT DETAIL, OMNIBASE
WITH STANDOFF TO RAFTER: SNR-DC-01249; SOLLEGA
FASTRACK510 WITH 304 STAINLESS STEEL HARDWARE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/15/2023 | RESIDENTIAL SOLAR v.2 | 03/21/2023 | APPROVED |
| 03/10/2023 | RESIDENTIAL SOLAR v.1 | 03/10/2023 | REQUIRES RESUBMIT |
Completed Inspections
Permit Status: Issued
Permit Number: TC-RES-0323-03356
Permit Description: • SYSTEM SIZE: 10540W DC, 7440W AC
• MODULES: (31) JA SOLAR: JAM60S10-340/MR
• INVERTERS: (31) ENPHASE ENERGY: IQ7-60-2-US
• RACKING: ULTRA RAIL, ATTACHMENT DETAIL, OMNIBASE
WITH STANDOFF TO RAFTER: SNR-DC-01249; SOLLEGA
FASTRACK510 WITH 304 STAINLESS STEEL HARDWARE
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/29/2023 | BULD - Electrical Clearance | Passed | Approved, DGC clearance to TEP is required for the solar meter | |
| 03/29/2023 | RSBU - Building Final | Passed | ||
| 03/29/2023 | COT - RSEL - Electrical Final | Passed |