Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address:
6055 E 5TH ST
Address NEW:
6055 E 5TH ST
Apply Date:
02/19/2026
Applicant:
TFS Solar
Description:
Roof mount 6.9 kW DC addition to existing photovoltaic solar system (new total system size: 14.92 kW), 16 additional modules, 2 branches to new 7.6kW Inverter. PV subpanel. Upsize pv disconnect to 100A. Service upgrade to NEW 200A Bus with 200A MCB. 80A PV breaker in auxiliary power source slot on new service panel (100A max.)

Permit Reviews

Permit Number - TC-RES-0226-00876
Permit Status: Complete
Permit Description: Roof mount 6.9 kW DC addition to existing photovoltaic solar system (new total system size: 14.92 kW), 16 additional modules, 2 branches to new 7.6kW Inverter. PV subpanel. Upsize pv disconnect to 100A. Service upgrade to NEW 200A Bus with 200A MCB. 80A PV breaker in auxiliary power source slot on new service panel (100A max.)
Start Date Submittal Complete Date Status  
02/20/2026 RESIDENTIAL SOLAR v.1 03/10/2026 REQUIRES RESUBMIT Review Details
03/10/2026 RESIDENTIAL SOLAR v.2 03/11/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-0226-00876
Permit Status: Complete
Permit Description: Roof mount 6.9 kW DC addition to existing photovoltaic solar system (new total system size: 14.92 kW), 16 additional modules, 2 branches to new 7.6kW Inverter. PV subpanel. Upsize pv disconnect to 100A. Service upgrade to NEW 200A Bus with 200A MCB. 80A PV breaker in auxiliary power source slot on new service panel (100A max.)
Date Description Comments
02/20/2026 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0226-00876
Permit Description: Roof mount 6.9 kW DC addition to existing photovoltaic solar system (new total system size: 14.92 kW), 16 additional modules, 2 branches to new 7.6kW Inverter. PV subpanel. Upsize pv disconnect to 100A. Service upgrade to NEW 200A Bus with 200A MCB. 80A PV breaker in auxiliary power source slot on new service panel (100A max.)
Total Completed Inspections - 3
Date Description Inspector Results Comments
04/29/2026 BULD - Electrical Clearance Passed 4.29.26
Approved for DGC clearance
04/29/2026 COT - RSOL - Electrical Final Solar Project Passed
04/29/2026 RSBU - Building Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
(SURGE PRO) SIE_SS_QSPD_V1.PDF DOCUMENTS VIEW
CONS-WEST ARNOLD PV ADD-RFC DRAWINGS_V2.PDF DOCUMENTS VIEW
WEST ARNOLD PV RFC NARRATIVE_V1.PDF DOCUMENTS VIEW