Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
1924 E 5TH ST
Address NEW:
1924 E 5TH ST
Apply Date:
02/09/2024
Applicant:
Shawn Hunter
Description:
Kitchen Extension; Laundry Room and Porch Additions

Permit Reviews

Permit Number - TC-RES-0224-00796
Permit Status: Inspections
Permit Description: Kitchen Extension; Laundry Room and Porch Additions
Start Date Submittal Complete Date Status  
02/12/2024 RESIDENTIAL NEW DWELLING v.1 03/13/2024 REQUIRES RESUBMIT Review Details
06/07/2024 RESIDENTIAL NEW DWELLING v.2 06/18/2024 APPROVED Review Details

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0224-00796
Permite Description: Kitchen Extension; Laundry Room and Porch Additions
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
06/03/2025 RSPL - Plumbing Progress N/A Partial Pass Plumbing underground for addition bathroom. Ok to cover when slab area has been termite treated.
06/02/2025 COT - RSBU - Masonry Pregrout N/A Not Ready 6.2.25 underground plumbing has not been inspected. Uncover and have under test to verify.
06/02/2025 COT - RSBU - Preslab N/A Not Ready 6.2.25 underground plumbing has not been inspected. Uncover and have under test to verify.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-RES-0224-00796
Permit Description: Kitchen Extension; Laundry Room and Porch Additions
Total Completed Inspections - 3
Date Description Inspector Results Comments
05/19/2025 COT - RSBU - Excavation/Rebar/Zoning Passed Footings for new addition. Ok to,place concrete in progress areas.
05/23/2025 COT - RSBU - Stem Wall/Retaining Wall Passed Reinforcements per plan. Okay to grout. 5/23/2025
01/26/2026 COT - RSPL - Sewer Passed