Permit: TC-RES-0126-00403
Permit Details
Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
5034 S MOUNTAIN AV
Address NEW:
5034 S MOUNTAIN AV
Apply Date:
01/26/2026
Applicant:
Bethuel Samu
Description:
Fire Damage Repair
Permit Reviews
Permit Number - TC-RES-0126-00403
Permit Status: Inspections complete
Permit Description: Fire Damage Repair
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/30/2026 | RESIDENTIAL ADD/ALT v.1 | 02/19/2026 | APPROVED |
Conditions
Permit Number - TC-RES-0126-00403
Permit Status: Inspections complete
Permit Description: Fire Damage Repair
| Date | Description | Comments |
|---|---|---|
| 01/30/2026 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-0126-00403
Permite Description: Fire Damage Repair
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/31/2026 | BULD - Electrical Clearance | N/A | Re-inspection required | 3-31-26: install plastic bushing inside main panel to protect non metallic awg wires, installed cover plate for junction box above disconnect and replace conduit for disconnect with armored cabling/conduit. Have electrician isolate taped awg wires inside main panel and cap each using electrical connectors. Also, ensure that a metallic address is installed at panel and install smoke detectors in each bedroom. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-0126-00403
Permit Description: Fire Damage Repair
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/31/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 3-31-26: corrections made from inspection dated 3/25/26. Okay to continue with construction at progress areas. | |
| 04/07/2026 | BULD - Electrical Clearance | Passed | 4.7.26 Approved for RECN |
|
| 05/15/2026 | COT - RSBU - Roof Nailing | Passed | 5/15/2026 Verified truss replacement in bathroom and h2.5 clips, approved per plan. |
|
| 05/15/2026 | COT - RSEL - Electrical Final | Passed | 5/15/2026 Approved per plan, added circuit schedule to main load center. |
|
| 05/14/2026 | COT - RSME - Mechanical Final | Passed | ||
| 05/15/2026 | RSBU - Building Final | Passed | 05/15/2026 Add air register cover in bathroom, label circuits at electrical panel, provide photos of roof joist replacement. |