Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Apply Date:
01/20/2026
Applicant:
Description:
Replace the existing underground gas service line from the gas meter to the residence. During a routine inspection, Southwest Gas identified an underground gas leak and shut off service at the meter. Install a new 1-inch polyethylene (PE) gas line from the meter to the house. The gas line will be installed underground at a minimum depth of 18 inches, with an approved tracer wire installed the full length of the piping. The new gas piping will be pressure tested per City of Tucson and adopted IFGC requirements and inspected prior to backfilling.

Permit Reviews

Permit Number - TC-RES-0126-00275
Permit Status: Complete
Permit Description: Replace the existing underground gas service line from the gas meter to the residence. During a routine inspection, Southwest Gas identified an underground gas leak and shut off service at the meter. Install a new 1-inch polyethylene (PE) gas line from the meter to the house. The gas line will be installed underground at a minimum depth of 18 inches, with an approved tracer wire installed the full length of the piping. The new gas piping will be pressure tested per City of Tucson and adopted IFGC requirements and inspected prior to backfilling.
Start Date Submittal Complete Date Status  
01/21/2026 RESIDENTIAL SIMPLE REVIEW v.1 01/21/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-0126-00275
Permit Status: Complete
Permit Description: Replace the existing underground gas service line from the gas meter to the residence. During a routine inspection, Southwest Gas identified an underground gas leak and shut off service at the meter. Install a new 1-inch polyethylene (PE) gas line from the meter to the house. The gas line will be installed underground at a minimum depth of 18 inches, with an approved tracer wire installed the full length of the piping. The new gas piping will be pressure tested per City of Tucson and adopted IFGC requirements and inspected prior to backfilling.
Date Description Comments
01/21/2026 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0126-00275
Permit Description: Replace the existing underground gas service line from the gas meter to the residence. During a routine inspection, Southwest Gas identified an underground gas leak and shut off service at the meter. Install a new 1-inch polyethylene (PE) gas line from the meter to the house. The gas line will be installed underground at a minimum depth of 18 inches, with an approved tracer wire installed the full length of the piping. The new gas piping will be pressure tested per City of Tucson and adopted IFGC requirements and inspected prior to backfilling.
Total Completed Inspections - 3
Date Description Inspector Results Comments
01/23/2026 COT - BULD - SWG Clearance Passed Verbal clearance to Southwest Gas. 1/23/2026
01/23/2026 RSBU - Building Final Passed
01/23/2026 COT - RSPL - Plumbing Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
331 N AVENIDA FELICIDAD GAS LINE_V1.PDF DOCUMENTS VIEW