Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
2046 E 4TH ST
Address NEW:
2046 E 4TH ST
Apply Date:
01/06/2026
Applicant:
TFS Solar
Description:
New Ground Mounted Structure for 8.60 kW DC photovoltaic solar system; 20 modules; 27 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 2 strings. 1 battery expansion pack, (no inverter). Trench from array to (E) Garage. 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.

Permit Reviews

Permit Number - TC-RES-0126-00062
Permit Status: Inspections
Permit Description: New Ground Mounted Structure for 8.60 kW DC photovoltaic solar system; 20 modules; 27 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 2 strings. 1 battery expansion pack, (no inverter). Trench from array to (E) Garage. 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.
Start Date Submittal Complete Date Status  
01/06/2026 RESIDENTIAL SOLAR v.1 01/13/2026 APPROVED Review Details

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0126-00062
Permite Description: New Ground Mounted Structure for 8.60 kW DC photovoltaic solar system; 20 modules; 27 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 2 strings. 1 battery expansion pack, (no inverter). Trench from array to (E) Garage. 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
06/15/2026 COT - RSBU - Excavation/Rebar/Zoning N/A Not Ready Footers were poured prior to rebar inspection. 6/15/2026
06/15/2026 COT - RSOL - Electrical Underground Solar Project N/A Partial Pass Partial pass. X2 1" schedule 40 conduit at an 18" depth from new structure to a box (pull point) behind inverter. Okay to backfill progress areas. Ensure caution tape is in place after 1st lift of compaction. 6/15/2026

Completed Inspections

Permit Status: Inspections
Permit Number: TC-RES-0126-00062
Permit Description: New Ground Mounted Structure for 8.60 kW DC photovoltaic solar system; 20 modules; 27 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 2 strings. 1 battery expansion pack, (no inverter). Trench from array to (E) Garage. 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.
Total Completed Inspections - 5
Date Description Inspector Results Comments
06/16/2026 COT - RSBU - Excavation/Rebar/Zoning Passed Approved per third party report. 6/16/2026
06/16/2026 COT - RSOL - Electrical Underground Solar Project Passed
06/16/2026 BULD - Electrical Clearance Passed Clearance for TEP DGC/BAT. 6/16/2026
06/16/2026 RSBU - Building Final Passed
06/16/2026 COT - RSOL - Electrical Final Solar Project Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
125322 TOMIZUKA RESIDENCE PV SYSTEM CALCULATION PACKAGE SEALED_V1.PDF DOCUMENTS VIEW
CONS-TOMIZUKA KIMBERLY PV STORAGE-DRAWINGS STAMPED_V1.PDF DOCUMENTS VIEW
TOMIZUKA KIMBERLY PV STORAGE-SPECS_V1.PDF DOCUMENTS VIEW