Permit: TC-RES-0125-00097
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
850 S MEYER AV
Address NEW:
850 S MEYER AV
Apply Date:
01/07/2025
Applicant:
TFS Solar
Description:
*Complete removal of old PV system. Installation of new system*: Roof mount 3.01kW DC photovoltaic solar system; 7 modules with microinverters, 1 branch, 20A PV breaker on 100A bus with 100A MCB. Existing 60A PV disconnect and solar meter base to be re-used.
Permit Reviews
Permit Number - TC-RES-0125-00097
Permit Status: Complete
Permit Description: *Complete removal of old PV system. Installation of new system*:
Roof mount 3.01kW DC photovoltaic solar system; 7 modules with microinverters, 1 branch, 20A PV breaker on 100A bus with 100A MCB.
Existing 60A PV disconnect and solar meter base to be re-used.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/08/2025 | RESIDENTIAL SOLAR v.1 | 02/05/2025 | APPROVED |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0125-00097
Permit Description: *Complete removal of old PV system. Installation of new system*:
Roof mount 3.01kW DC photovoltaic solar system; 7 modules with microinverters, 1 branch, 20A PV breaker on 100A bus with 100A MCB.
Existing 60A PV disconnect and solar meter base to be re-used.
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/10/2025 | BULD - Electrical Clearance | Passed | ||
| 04/10/2025 | RSBU - Building Final | Passed | ||
| 04/10/2025 | COT - RSOL - Electrical Final Solar Project | Passed |