Daniel Smith
Description:
SW gas pinned meter for gas smell. At tankless and drop test failure. We will replace both of the flex gas connectors to the stove and tankless install a sediment trap on the tankless. perform a drop test on all existing piping. 180,000 total BTU 14 ft of 3/4 steel piping.

Permit Reviews

Permit Number - TC-RES-0124-00436
Permit Status: Issued
Permit Description: SW gas pinned meter for gas smell. At tankless and drop test failure. We will replace both of the flex gas connectors to the stove and tankless install a sediment trap on the tankless. perform a drop test on all existing piping. 180,000 total BTU 14 ft of 3/4 steel piping.
Start Date Submittal Complete Date Status  
01/25/2024 RESIDENTIAL SIMPLE REVIEW v.1 01/25/2024 APPROVED Review Details

Completed Inspections

Permit Status: Issued
Permit Number: TC-RES-0124-00436
Permit Description: SW gas pinned meter for gas smell. At tankless and drop test failure. We will replace both of the flex gas connectors to the stove and tankless install a sediment trap on the tankless. perform a drop test on all existing piping. 180,000 total BTU 14 ft of 3/4 steel piping.
Total Completed Inspections - 3
Date Description Inspector Results Comments
02/07/2024 RSPL - Plumbing Progress Passed new gas lines have been installed for stove/oven and water heater. gas line is under an air test and holding 15# of air without leaking.
02/07/2024 COT - BULD - SWG Clearance Passed new gas lines have been installed for stove/oven and water heater. gas line is under an air test and holding 15# of air without leaking.
02/07/2024 COT - RSPL - Plumbing Final Passed new gas lines have been installed for stove/oven and water heater. gas line is under an air test and holding 15# of air without leaking.