Permit: TC-RES-0123-02355
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
3633 S LUNDY AV
Address NEW:
3633 S LUNDY AV
Apply Date:
01/25/2023
Applicant:
BRANDY PALCHETTI
Description:
• SYSTEM SIZE: 6800W DC, 5800W AC • MODULES: (20) JA SOLAR: JAM60S10-340/MR • INVERTERS: (20) ENPHASE ENERGY: IQ7PLUS-72-2-US • RACKING: ULTRA RAIL SPEEDSEAL FOOT, SEE DRAWING SNR-DC-00438; SOLLEGA FASTRACK510 WITH 304 STAINLESS STEEL HARDWARE
Permit Reviews
Permit Number - TC-RES-0123-02355
Permit Status: Issued
Permit Description: • SYSTEM SIZE: 6800W DC, 5800W AC
• MODULES: (20) JA SOLAR: JAM60S10-340/MR
• INVERTERS: (20) ENPHASE ENERGY: IQ7PLUS-72-2-US
• RACKING: ULTRA RAIL SPEEDSEAL FOOT, SEE DRAWING
SNR-DC-00438; SOLLEGA FASTRACK510 WITH 304
STAINLESS STEEL HARDWARE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/25/2023 | RESIDENTIAL SOLAR v.1 | 02/13/2023 | APPROVED |
| 03/03/2023 | RESIDENTIAL SOLAR v.1 | 03/07/2023 | APPROVED |
Completed Inspections
Permit Status: Issued
Permit Number: TC-RES-0123-02355
Permit Description: • SYSTEM SIZE: 6800W DC, 5800W AC
• MODULES: (20) JA SOLAR: JAM60S10-340/MR
• INVERTERS: (20) ENPHASE ENERGY: IQ7PLUS-72-2-US
• RACKING: ULTRA RAIL SPEEDSEAL FOOT, SEE DRAWING
SNR-DC-00438; SOLLEGA FASTRACK510 WITH 304
STAINLESS STEEL HARDWARE
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/29/2023 | BULD - Electrical Clearance | Passed | DGC | |
| 03/29/2023 | RSBU - Building Final | Passed | DGC | |
| 03/29/2023 | COT - RSEL - Electrical Final | Passed | DGC |