Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Apply Date:
01/04/2023
Applicant:
Sue Wilson
Description:
Interior hot & cold repipe of the domestic water distribution system.

Permit Reviews

Permit Number - TC-RES-0123-01879
Permit Status: Issued
Permit Description: Interior hot & cold repipe of the domestic water distribution system.
Start Date Submittal Complete Date Status  
01/05/2023 COMMERCIAL PDSD SIMPLE REVIEW v.1 01/05/2023 APPROVED Review Details

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-RES-0123-01879
Permite Description: Interior hot & cold repipe of the domestic water distribution system.
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
01/11/2023 RSPL - Plumbing Progress N/A Not Ready leak underneath kitchen sink(loose fitting)
missing hammer arrestor for dishwasher
fire stop all top penetrations (including holes that are not being used)
need 18” of clearance for copper to pex line.(back yard)
low water pressure.

Completed Inspections

Permit Status: Issued
Permit Number: TC-RES-0123-01879
Permit Description: Interior hot & cold repipe of the domestic water distribution system.
Total Completed Inspections - 1
Date Description Inspector Results Comments
01/12/2023 COT - RSPL - Plumbing Final Passed Ok to patch areas throughout the structure.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW