Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Model Building Permit
Address NEW:
4695 E JULIAN WASH DR
Apply Date:
11/08/2024
Applicant:
Description:
SFR MERI156021 T21-M0063 (Model Master Plan TC-MDP-0123-00387)

Permit Reviews

Permit Number - TC-MDP-1124-01290
Permit Status: Complete
Permit Description: SFR MERI156021 T21-M0063 (Model Master Plan TC-MDP-0123-00387)
Start Date Submittal Complete Date Status  
11/15/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 12/05/2024 APPROVED Review Details
09/04/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 09/08/2025 APPROVED Review Details

Conditions

Permit Number - TC-MDP-1124-01290
Permit Status: Complete
Permit Description: SFR MERI156021 T21-M0063 (Model Master Plan TC-MDP-0123-00387)
Date Description Comments
11/08/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
11/19/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
11/19/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
11/19/2024 Post-Tension Inspection Report is required.
11/08/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
11/08/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
11/19/2024 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
11/19/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-MDP-1124-01290
Permite Description: SFR MERI156021 T21-M0063 (Model Master Plan TC-MDP-0123-00387)
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
07/07/2025 COT - RSBU - Roof Nailing N/A Re-inspection required 7.7.25
Shot pins required 6 inch from edge of sole plate throughout on (non load bearing). Install anchor bolts as marked, locations, Anchor bolts required within 12" of edge of exterior sole plates. A35s missing nails in multiple areas. RSP 4s required every other stud-add to marked locations, add h-25 at truss CG48C, loose roof panel on bedroom located on south-side.
07/07/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 7.7.25
Shot pins required 6 inch from edge of sole plate throughout on (non load bearing). Install anchor bolts as marked, locations, Anchor bolts required within 12" of edge of exterior sole plates. A35s missing nails in multiple areas. RSP 4s required every other stud-add to marked locations, add h-25 at truss CG48C, loose roof panel on bedroom located on south-side.
09/15/2025 RSBU - Building Final N/A Not Ready
09/15/2025 ENGR Engineering Final N/A Not Ready Street directly in front of driveway is impassable, access to home is prevented. Not ready for inspection, recall when street work is complete.

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-1124-01290
Permit Description: SFR MERI156021 T21-M0063 (Model Master Plan TC-MDP-0123-00387)
Total Completed Inspections - 21
Date Description Inspector Results Comments
06/13/2025 COT - RSPL - Rough Soil Passed 6.13.25 Running water observed at bib, tracer wires present, all plumbing verified as per plan. Ok to backfill, proper shading material required.
06/13/2025 COT - RSPL - Sewer Passed 6.13.25 Running water observed at bib, tracer wires present, all plumbing verified as per plan. Ok to backfill, proper shading material required.
06/13/2025 COT - RSPL - Yard Water Line Passed 6.13.25 Running water observed at bib, tracer wires present, all plumbing verified as per plan. Ok to backfill, proper shading material required.
06/23/2025 COT - RSBU - Excavation/Rebar/Zoning Passed
06/23/2025 COT - RSBU - Preslab Passed
06/23/2025 COT - RSEL - Electrical Underground Passed
07/09/2025 COT - RSBU - Roof Nailing Passed 7-9-25: roof nailing approved
07/10/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 7-10-25: exterior clips/sheathing approved. Okay to continue with construction
07/17/2025 BULD - Electrical Clearance Passed Passed 7/17/25 CLEARANCE ECO
07/17/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Passed 7/17/25
07/17/2025 COT - RSPL - Gas Pressure Test Passed Passed 7/17/25
08/01/2025 COT - RSBU - Interior Shear Bracing Passed
09/03/2025 COT - BULD - SWG Clearance Passed 9.3.2025
Clearance for SW Gas.
09/09/2025 COT - RSEL - Grounding/Bonding Passed
09/09/2025 COT - RSEL - Outdoor Lighting Passed
09/09/2025 COT - RSME - Mechanical Final Passed
09/15/2025 RSBU - Building Progress Passed
09/15/2025 COT - RSEL - Electrical Final Passed
09/18/2025 COT - RSPL - Plumbing Final Passed 9-18-25: plumbing final approved.
09/18/2025 RSBU - Building Final Passed 9-18-25: building final approved.
09/30/2025 ENGR Engineering Final Passed Site is clear and accessible, built in accordance with approved plans.

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
241720 VALENCIA CROSSING LOT 120 PT-2025-09-02_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LOT 120 PLOT PLAN_V1.PDF DOCUMENTS VIEW
LOT 120 SPECIAL INSPECTION CERTIFICATE-2024-11-08_V1.PDF DOCUMENTS VIEW