Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-1123-01837
Permit Details
Apply Date:
01/23/2024
Applicant:
Craig Morczynski
Description:
SFR LENNLE4002 T22-M0046
Permit Reviews
Permit Number - TC-MDP-1123-01837
Permit Status: Issued
Permit Description: SFR LENNLE4002 T22-M0046
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/23/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 01/29/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-1123-01837
Permit Status: Issued
Permit Description: SFR LENNLE4002 T22-M0046
Total Outstanding Activity Conditions - 7
Date | Name |
---|---|
01/23/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
01/23/2024 | Post-Installed Anchor Inspection Report is required. |
01/23/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
01/25/2024 | Post-Tension Inspection Report is required. |
01/25/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
07/14/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
07/14/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Conditions
Permit Number - TC-MDP-1123-01837
Permit Status: Issued
Permit Description: SFR LENNLE4002 T22-M0046
Date | Description | Comments |
---|---|---|
11/27/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-MDP-1123-01837
Permite Description: SFR LENNLE4002 T22-M0046
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/29/2024 | COT - RSBU - Exterior Clips/Sheathing | N/A | Re-inspection required | Workers in house. Duct, work tools, and materials scattered all throughout house floor. Cannot conduct proper inspection. 4/29/24: shearing at north east corner of house need to be properly fastened, RSP4 clips missing throughout, 3 consecutive masa clips with one leg up please add anchor bolt to meet appropriate spacing, Anchor bolts throughout, Anchor bolt greater than 12" from sill plate at shear wall, H2.5 missing at master bedroom, roof nailing needs to be properly fastened throughout edges and field, |
04/29/2024 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | Workers in house. Duct, work tools, and materials scattered all throughout house floor. Cannot conduct proper inspection. 4/29/24: shearing at north east corner of house need to be properly fastened, RSP4 clips missing throughout, 3 consecutive masa clips with one leg up please add anchor bolt to meet appropriate spacing, Anchor bolts throughout, Anchor bolt greater than 12" from sill plate at shear wall, H2.5 missing at master bedroom, roof nailing needs to be properly fastened throughout edges and field, |
Completed Inspections
Permit Status: Issued
Permit Number: TC-MDP-1123-01837
Permit Description: SFR LENNLE4002 T22-M0046
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/11/2024 | COT - RSPL - Yard Water Line | Passed | 3/11/24: Main water is connected to the water meter and under street pressure with no leaks. Okay to shade pipe and backfill trenches. | |
03/11/2024 | COT - RSPL - Sewer | Passed | 3/11/24: Underground plumbing is connected to main sewer line and under a 10' water test with no leaks in the pipes. Okay to shade pipes and backfill trenches. | |
03/11/2024 | COT - RSPL - Rough Soil | Passed | 3/11/24: Underground plumbing is connected to main sewer line and under a 10' water test with no leaks in the pipes. Okay to shade pipes and backfill trenches. | |
03/25/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Missing masa clips | |
03/25/2024 | COT - RSBU - Preslab | Passed | Missing masa clips | |
03/25/2024 | COT - RSEL - Electrical Underground | Passed | Missing masa clips | |
03/25/2024 | COT - RSEL - Grounding/Bonding | Passed | Missing masa clips | |
05/06/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | ||
05/06/2024 | COT - RSBU - Roof Nailing | Passed | ||
05/17/2024 | BULD - Electrical Clearance | Passed | ||
06/24/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
06/24/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
06/24/2024 | RSBU - Building Progress | Passed | ||
07/05/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
09/09/2024 | COT - BULD - SWG Clearance | Passed | ||
09/23/2024 | RSBU - Building Final | Passed | 9/23/24 passed. | |
09/23/2024 | ENGR Engineering Final | Passed | ||
09/23/2024 | COT - RSPL - Plumbing Final | Passed | passed 9/23/24 | |
09/23/2024 | COT - RSME - Mechanical Final | Passed | 9/23/24 passed. | |
09/23/2024 | COT - RSEL - Outdoor Lighting | Passed | 9/23/24 passed. | |
09/23/2024 | COT - RSEL - Electrical Final | Passed | 9/23/24 |