Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Model Building Permit
Apply Date:
02/13/2024
Applicant:
Celina Rodriguez
Description:
Bella Tierra Phase 3 1745-130

Permit Reviews

Permit Number - TC-MDP-1123-01819
Permit Status: Inspections complete
Permit Description: Bella Tierra Phase 3 1745-130
Start Date Submittal Complete Date Status  
02/14/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 02/26/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-1123-01819
Permit Status: Inspections complete
Permit Description: Bella Tierra Phase 3 1745-130
Total Outstanding Activity Conditions - 5
Date Name
01/05/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
02/14/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
02/14/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
08/23/2023 Post-Tension Inspection Report is required.
08/23/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-MDP-1123-01819
Permit Status: Inspections complete
Permit Description: Bella Tierra Phase 3 1745-130
Date Description Comments
01/05/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
08/11/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-1123-01819
Permite Description: Bella Tierra Phase 3 1745-130
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
04/05/2024 COT - RSEL - Electrical Underground N/A Not Applicable Not required on this model, kitchen has a peninsula not an island.
05/08/2024 COT - RSBU - Exterior Clips/Sheathing N/A Re-inspection required Missing a/b bolts in 5 different places on shear walls throughout house.
10/10/2024 RSBU - Building Progress N/A Not Applicable
10/10/2024 COT - RSEL - Electrical Final N/A Re-inspection required 10/10/24 no clean outs at exterior, master bedroom closest switch not fastened, toilets need to be caulked, no ladder provided for crawl space.
10/10/2024 COT - RSME - Mechanical Final N/A Re-inspection required 10/10/24 no clean outs at exterior, master bedroom closest switch not fastened, toilets need to be caulked, no ladder provided for crawl space.
10/10/2024 COT - RSPL - Plumbing Final N/A Re-inspection required 10/10/24 no clean outs at exterior, master bedroom closest switch not fastened, toilets need to be caulked, no ladder provided for crawl space.
10/10/2024 RSBU - Building Final N/A Re-inspection required 10/10/24 no clean outs at exterior, master bedroom closest switch not fastened, toilets need to be caulked, no ladder provided for crawl space.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-1123-01819
Permit Description: Bella Tierra Phase 3 1745-130
Total Completed Inspections - 19
Date Description Inspector Results Comments
03/19/2024 COT - RSPL - Yard Water Line Passed
04/05/2024 COT - RSBU - Excavation/Rebar/Zoning Passed Concrete forms are in place, post tension cabling is properly installed per plans, rebar reinforcement is installed where required by the plan, Ufer ground rebar is attached to bottom rebar in footing, and footings are properly dug out and cleaned of debris.
04/05/2024 COT - RSBU - Preslab Passed Concrete forms are in place, post tension cabling is properly installed per plans, rebar reinforcement is installed where required by the plan, Ufer ground rebar is attached to bottom rebar in footing, and footings are properly dug out and cleaned of debris.
04/05/2024 COT - RSEL - Grounding/Bonding Passed Concrete forms are in place, post tension cabling is properly installed per plans, rebar reinforcement is installed where required by the plan, Ufer ground rebar is attached to bottom rebar in footing, and footings are properly dug out and cleaned of debris.
05/08/2024 COT - RSBU - Roof Nailing Passed Roof trusses are properly installed and secured to top plate with H2.5 clips. Roof sheathing is properly nailed to trusses per code. Okay to proceed with top out of plumbing.
05/10/2024 COT - RSBU - Exterior Clips/Sheathing Passed 5-10-24: Missing A/B bolts have been installed on all shear walls. Okay to proceed.
06/05/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with installation of insulation and drywall.
06/05/2024 COT - RSPL - Gas Pressure Test Passed Gas line is installed and holding 15# of air pressure with no leaks. Okay to proceed.
06/21/2024 COT - RSBU - Interior Shear Bracing Passed
08/02/2024 BULD - Electrical Clearance Passed TEP issued an ECO Clearance. Okay to energize panel.
08/27/2024 COT - BULD - SWG Clearance Passed SWG for meter only
09/09/2024 COT - RSPL - Sewer Passed Sewer line is properly connected to underground plumbing. Okay to shade pipe and backfill trench.
09/09/2024 COT - RSPL - Rough Soil Passed Sewer line is properly connected to underground plumbing. Okay to shade pipe and backfill trench.
10/10/2024 COT - RSEL - Outdoor Lighting Passed 10/10/24 pass
10/11/2024 COT - RSEL - Electrical Final Passed 10/11/24: Construction is complete per plans. Okay to issue Certificate of Occupancy.
10/11/2024 COT - RSME - Mechanical Final Passed 10/11/24: Construction is complete per plans. Okay to issue Certificate of Occupancy.
10/11/2024 COT - RSPL - Plumbing Final Passed 10/11/24: Construction is complete per plans. Okay to issue Certificate of Occupancy.
10/11/2024 RSBU - Building Final Passed 10/11/24: Construction is complete per plans. Okay to issue Certificate of Occupancy.
10/11/2024 ENGR Engineering Final Passed fix broken sidewalk