Permit: TC-MDP-1123-01784
Permit Details
Status:
Complete
Type:
Model Building Permit
Address:
4782 E GREENWAY WASH DR
Address NEW:
4782 E GREENWAY WASH DR
Apply Date:
12/29/2023
Applicant:
Dana Petty
Description:
SFR MERI213021 T21-M0065
Permit Reviews
Permit Number - TC-MDP-1123-01784
Permit Status: Complete
Permit Description: SFR MERI213021 T21-M0065
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/21/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 06/21/2024 | APPROVED |
| 12/29/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 01/04/2024 | APPROVED |
| 09/26/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/27/2024 | APPROVED |
Conditions
Permit Number - TC-MDP-1123-01784
Permit Status: Complete
Permit Description: SFR MERI213021 T21-M0065
| Date | Description | Comments |
|---|---|---|
| 12/29/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
| 12/29/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 12/29/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 01/02/2024 | Post-Tension Inspection Report is required. | |
| 11/07/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 12/29/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
| 12/29/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
| 01/02/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-1123-01784
Permite Description: SFR MERI213021 T21-M0065
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 6/21/24: properly secure thermostat wire in wall at second floor, seal all penetrations through vapor barrier and top plate, properly support Flex duct at first floor, properly support range exhaust. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-1123-01784
Permit Description: SFR MERI213021 T21-M0065
Total Completed Inspections - 22