Permit: TC-MDP-1123-01782
Permit Details
Apply Date:
11/07/2023
Applicant:
Celina Rodriguez
Description:
SFR BT2013-140 T22-M0036
Permit Reviews
Permit Number - TC-MDP-1123-01782
Permit Status: Inspections complete
Permit Description: SFR BT2013-140 T22-M0036
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
11/08/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 11/15/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-1123-01782
Permit Status: Inspections complete
Permit Description: SFR BT2013-140 T22-M0036
Total Outstanding Activity Conditions - 4
Date | Name |
---|---|
11/08/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
11/08/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
11/14/2023 | Post-Tension Inspection Report is required. |
11/14/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-1123-01782
Permit Status: Inspections complete
Permit Description: SFR BT2013-140 T22-M0036
Date | Description | Comments |
---|---|---|
11/07/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
11/08/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1123-01782
Permite Description: SFR BT2013-140 T22-M0036
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/12/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 2/12/24: notched double top plate needs ties installed. Missing anchor bolts at shear walls. DWV not under test. Missing nail plate a laundry room. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1123-01782
Permit Description: SFR BT2013-140 T22-M0036
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/29/2023 | COT - RSPL - Yard Water Line | Passed | Water line is under 80 psi compressed air from meter box to connection point at house. | |
11/29/2023 | COT - RSPL - Sewer | Passed | Underground plumbing is connected to main sewer line. Okay to shade pipe and backfill trenches. | |
11/29/2023 | COT - RSPL - Rough Soil | Passed | Underground plumbing is complete and under a 10' water test. Okay to shade pipe and backfill trenches. | |
12/06/2023 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
12/06/2023 | COT - RSBU - Preslab | Passed | ||
12/06/2023 | COT - RSEL - Electrical Underground | Passed | ||
12/06/2023 | COT - RSEL - Grounding/Bonding | Passed | ||
12/21/2023 | COT - RSBU - Exterior Clips/Sheathing | Passed | 12/21/23: missing anchor bolts at shear walls okay to proceed to intermediates will check for them then | |
12/21/2023 | COT - RSBU - Roof Nailing | Passed | ||
02/12/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
02/13/2024 | BULD - Electrical Clearance | Passed | TEP eco | |
02/20/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
02/29/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
04/23/2024 | COT - BULD - SWG Clearance | Passed | Clearance for SOUTHWEST GAS. 4/23/2024 | |
05/06/2024 | COT - RSEL - Electrical Final | Passed | Construction, mechanical, electrical, and plumbing work is complete. Mechanical, electrical, and plumbing fixtures are installed and operational. AFCI & GFCI breakers are installed in electrical panel for bedrooms, kitchen, bathrooms, exterior outlets, laundry room, and garage. Okay to issue Certificate of Occupancy once all other agencies approve permit. | |
05/06/2024 | COT - RSEL - Outdoor Lighting | Passed | Outdoor lighting is installed and operational per plans and code requirements. | |
05/06/2024 | COT - RSME - Mechanical Final | Passed | Construction, mechanical, electrical, and plumbing work is complete. Mechanical, electrical, and plumbing fixtures are installed and operational. AFCI & GFCI breakers are installed in electrical panel for bedrooms, kitchen, bathrooms, exterior outlets, laundry room, and garage. Okay to issue Certificate of Occupancy once all other agencies approve permit. | |
05/06/2024 | COT - RSPL - Plumbing Final | Passed | Construction, mechanical, electrical, and plumbing work is complete. Mechanical, electrical, and plumbing fixtures are installed and operational. AFCI & GFCI breakers are installed in electrical panel for bedrooms, kitchen, bathrooms, exterior outlets, laundry room, and garage. Okay to issue Certificate of Occupancy once all other agencies approve permit. | |
05/06/2024 | RSBU - Building Final | Passed | Construction, mechanical, electrical, and plumbing work is complete. Mechanical, electrical, and plumbing fixtures are installed and operational. AFCI & GFCI breakers are installed in electrical panel for bedrooms, kitchen, bathrooms, exterior outlets, laundry room, and garage. Okay to issue Certificate of Occupancy once all other agencies approve permit. | |
05/06/2024 | ENGR Engineering Final | Passed | ||
05/06/2024 | RSBU - Building Progress | Passed | Complete |