Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Model Building Permit
Address NEW:
9756 E GRAY HAWK DR
Apply Date:
11/01/2023
Applicant:
Helen Ormsby
Description:
Casas del Cerrito 3542 Model Plan

Permit Reviews

Permit Number - TC-MDP-1123-01732
Permit Status: Inspections complete
Permit Description: Casas del Cerrito 3542 Model Plan
Start Date Submittal Complete Date Status  
04/12/2024 SITE FROM MODEL PERMIT - SUBDIVISION v.2 04/18/2024 APPROVED Review Details
08/09/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 08/13/2024 APPROVED Review Details
04/18/2024 RESTAMP - RESIDENTIAL v.1 04/18/2024 APPROVED Review Details
03/01/2024 SITE FROM MODEL PERMIT - SUBDIVISION v.1 03/08/2024 REQUIRES RESUBMIT Review Details
02/06/2024 SITE FROM MODEL PERMIT - SUBDIVISION v.2 02/13/2024 APPROVED Review Details
11/03/2023 SITE FROM MODEL PERMIT - SUBDIVISION v.1 11/13/2023 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-MDP-1123-01732
Permit Status: Inspections complete
Permit Description: Casas del Cerrito 3542 Model Plan
Date Description Comments
11/03/2023 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
11/03/2023 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
11/13/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
11/13/2023 Post-Tension Inspection Report is required.
08/12/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
08/24/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
11/03/2023 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
11/13/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-1123-01732
Permit Description: Casas del Cerrito 3542 Model Plan
Total Completed Inspections - 22
Date Description Inspector Results Comments
05/01/2024 COT - RSPL - Backwater Valve Passed Underground plumbing is complete and connected to city sewer. Backwater valve is installed between clean outs. Complete system is under a water test with no leaks. Okay to shade pipes and backfill trenches.
05/01/2024 COT - RSPL - Rough Soil Passed Underground plumbing is complete and connected to city sewer. Backwater valve is installed between clean outs. Complete system is under a water test with no leaks. Okay to shade pipes and backfill trenches.
05/01/2024 COT - RSPL - Sewer Passed Underground plumbing is complete and connected to city sewer. Backwater valve is installed between clean outs. Complete system is under a water test with no leaks. Okay to shade pipes and backfill trenches.
05/01/2024 COT - RSPL - Yard Water Line Passed Main water line is connected to the city water system with a meter. System is under street pressure with no leaks. Okay to shade pipe and backfill trench.
05/10/2024 COT - RSBU - Preslab Passed Concrete forms are set, post tension cabling is installed, underground electrical is in place, Ufer ground is in place on left side of garage, required shear wall hold downs are in place and connected to rebar reinforcement, masa clips are evenly spaced around outside edge of form, and all underground plumbing pipes are wrapped with foam and all bathtub or shower stall drain lines are blocked out properly. Okay to pour concrete for footings and slab on grade.
05/10/2024 COT - RSEL - Electrical Underground Passed Concrete forms are set, post tension cabling is installed, underground electrical is in place, Ufer ground is in place on left side of garage, required shear wall hold downs are in place and connected to rebar reinforcement, masa clips are evenly spaced around outside edge of form, and all underground plumbing pipes are wrapped with foam and all bathtub or shower stall drain lines are blocked out properly. Okay to pour concrete for footings and slab on grade
05/10/2024 BULD - Electrical Clearance Passed Electrical panel is installed with 2 ground rods 6 plus feet apart. TEP ECO Clearance issued.
05/10/2024 COT - RSBU - Excavation/Rebar/Zoning Passed Concrete forms are set, post tension cabling is installed, underground electrical is in place, Ufer ground is in place on left side of garage, required shear wall hold downs are in place and connected to rebar reinforcement, masa clips are evenly spaced around outside edge of form, and all underground plumbing pipes are wrapped with foam and all bathtub or shower stall drain lines are blocked out properly. Okay to pour concrete for footings and slab on grade.
05/10/2024 COT - RSEL - Grounding/Bonding Passed Concrete forms are set, post tension cabling is installed, underground electrical is in place, Ufer ground is in place on left side of garage, required shear wall hold downs are in place and connected to rebar reinforcement, masa clips are evenly spaced around outside edge of form, and all underground plumbing pipes are wrapped with foam and all bathtub or shower stall drain lines are blocked out properly. Okay to pour concrete for footings and slab on grade.
06/03/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Exterior walls are properly secured to concrete floor with shot pins, a/b bolts, and masa clips. Shear wall is properly secured per the plan.
06/03/2024 COT - RSBU - Roof Nailing Passed Roof trusses are properly nailed and secured to the top plate with nails and H2.5 clips nailed per code.
06/18/2024 COT - RSPL - Gas Pressure Test Passed
06/21/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
06/27/2024 COT - RSBU - Interior Shear Bracing Passed
08/13/2024 COT - BULD - SWG Clearance Passed
08/14/2024 RSBU - Building Progress Passed
08/14/2024 COT - RSEL - Outdoor Lighting Passed Outdoor lighting is properly installed and functional per building plan and city guidelines.
08/26/2024 COT - RSME - Mechanical Final Passed Passed--Construction is completed. Mechanical and plumbing fixtures are installed and operational. Electrical panel dead front is not properly installed breakers need adjustments to allow dead front to be tight to edges of breakers. All outdoor receptacles need to be WR rated. Landscaping needs to be replaced after sewer line repair.
08/26/2024 COT - RSPL - Plumbing Final Passed Passed--Construction is completed. Mechanical and plumbing fixtures are installed and operational. Electrical panel dead front is not properly installed breakers need adjustments to allow dead front to be tight to edges of breakers. All outdoor receptacles need to be WR rated. Landscaping needs to be replaced after sewer line repair.
09/05/2024 COT - RSEL - Electrical Final Passed Construction is complete. Okay to issue Certificate of Occupancy.
09/05/2024 ENGR Engineering Final Passed
09/05/2024 RSBU - Building Final Passed Construction is complete. Okay to issue Certificate of Occupancy.

Documents

File Name Document Type  
CDC 40 SIC-2024-08-07_V1.PDF DOCUMENTS VIEW
CDC 40 RFC LETTER_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CDC 40 SIC-2023-11-02_V1.PDF DOCUMENTS VIEW
CDC AVP RELEASE_V1.PDF DOCUMENTS VIEW