Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-1123-01714
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
9757 E GRAY HAWK DR
Address NEW:
9757 E GRAY HAWK DR
Apply Date:
11/02/2023
Applicant:
Helen Ormsby
Description:
Casas del Cerrito H35D Model Plan
Permit Reviews
Permit Number - TC-MDP-1123-01714
Permit Status: Inspections complete
Permit Description: Casas del Cerrito H35D Model Plan
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/06/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.2 | 02/13/2024 | APPROVED |
| 11/03/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 11/13/2023 | REQUIRES RESUBMIT |
| 07/18/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 07/19/2024 | APPROVED |
Conditions
Permit Number - TC-MDP-1123-01714
Permit Status: Inspections complete
Permit Description: Casas del Cerrito H35D Model Plan
| Date | Description | Comments |
|---|---|---|
| 11/03/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
| 11/03/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 11/13/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 11/13/2023 | Post-Tension Inspection Report is required. | |
| 11/02/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 11/03/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
| 11/13/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1123-01714
Permit Description: Casas del Cerrito H35D Model Plan
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/01/2024 | COT - RSPL - Backwater Valve | Passed | Underground plumbing is complete and connected to city sewer. Backwater valve is installed between clean outs. Complete system is under a water test with no leaks. Okay to shade pipes and backfill trenches. | |
| 05/01/2024 | COT - RSPL - Rough Soil | Passed | Underground plumbing is complete and connected to city sewer. Backwater valve is installed between clean outs. Complete system is under a water test with no leaks. Okay to shade pipes and backfill trenches. | |
| 05/01/2024 | COT - RSPL - Sewer | Passed | Underground plumbing is complete and connected to city sewer. Backwater valve is installed between clean outs. Complete system is under a water test with no leaks. Okay to shade pipes and backfill trenches. | |
| 05/01/2024 | COT - RSPL - Yard Water Line | Passed | Main water line is connected to the city water with a meter and is under street pressure. Okay to shade pipe and backfill trench. | |
| 05/09/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 05/09/2024 | COT - RSBU - Preslab | Passed | ||
| 05/09/2024 | COT - RSEL - Electrical Underground | Passed | ||
| 05/09/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
| 05/21/2024 | BULD - Electrical Clearance | Passed | TEP ECO | |
| 05/28/2024 | COT - RSBU - Roof Nailing | Passed | ||
| 05/29/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 06/12/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with installation of insulation and drywall throughout. | |
| 06/12/2024 | COT - RSPL - Gas Pressure Test | Passed | Gas line is under 15# of air pressure with no leaks. Okay to proceed. | |
| 06/12/2024 | RSBU - Building Progress | Passed | Mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with installation of insulation and drywall throughout. | |
| 06/24/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 07/31/2024 | COT - BULD - SWG Clearance | Passed | Clearance for Southwest Gas. 7/31/2024 | |
| 08/16/2024 | COT - RSEL - Electrical Final | Passed | Construction is complete. Mechanical, electrical, and plumbing fixtures are installed and fully functional. Electrical panel is properly labeled with AFCI & GFCI breakers installed as required. GFCI outlets in bathrooms are fully operational. Okay to issue Certificate of Occupancy. | |
| 08/16/2024 | COT - RSEL - Outdoor Lighting | Passed | Construction is complete. Mechanical, electrical, and plumbing fixtures are installed and fully functional. Electrical panel is properly labeled with AFCI & GFCI breakers installed as required. GFCI outlets in bathrooms are fully operational. Okay to issue Certificate of Occupancy. | |
| 08/16/2024 | COT - RSME - Mechanical Final | Passed | Construction is complete. Mechanical, electrical, and plumbing fixtures are installed and fully functional. Electrical panel is properly labeled with AFCI & GFCI breakers installed as required. GFCI outlets in bathrooms are fully operational. Okay to issue Certificate of Occupancy. | |
| 08/16/2024 | COT - RSPL - Plumbing Final | Passed | Construction is complete. Mechanical, electrical, and plumbing fixtures are installed and fully functional. Electrical panel is properly labeled with AFCI & GFCI breakers installed as required. GFCI outlets in bathrooms are fully operational. Okay to issue Certificate of Occupancy. | |
| 08/16/2024 | RSBU - Building Final | Passed | Construction is complete. Mechanical, electrical, and plumbing fixtures are installed and fully functional. Electrical panel is properly labeled with AFCI & GFCI breakers installed as required. GFCI outlets in bathrooms are fully operational. Okay to issue Certificate of Occupancy. | |
| 09/05/2024 | ENGR Engineering Final | Passed |