Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-1023-01700
Permit Details
Apply Date:
12/15/2023
Applicant:
Joshua Swinney
Description:
Eisenhower Model Plan La Escalera
Permit Reviews
Permit Number - TC-MDP-1023-01700
Permit Status: Complete
Permit Description: Eisenhower Model Plan La Escalera
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/18/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.2 | 09/19/2024 | APPROVED |
09/10/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/11/2024 | REQUIRES RESUBMIT |
12/15/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 12/26/2023 | APPROVED |
Conditions
Permit Number - TC-MDP-1023-01700
Permit Status: Complete
Permit Description: Eisenhower Model Plan La Escalera
Date | Description | Comments |
---|---|---|
12/26/2023 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as a contact. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
04/15/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
01/20/2023 | Post-Tension Inspection Report is required. | |
04/15/2024 | Post-Tension Inspection Report is required. | |
10/25/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
12/12/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
04/15/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
12/12/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
01/20/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. | |
04/15/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-1023-01700
Permite Description: Eisenhower Model Plan La Escalera
Total Outstanding Inspections - 8
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/01/2024 | COT - RSBU - Interior Shear Bracing | N/A | Re-inspection required | Not ready. Screw pattern not per schedule. 7/1/2024 |
08/16/2024 | COT - BULD - SWG Clearance | N/A | Not Applicable | Not Applicable for this project. There is no gas on this residence. |
08/16/2024 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | Not Applicable for this project. There is no gas on this residence. |
09/27/2024 | COT - RSEL - Electrical Final | N/A | Re-inspection required | Needs smoke detectors on first floor. Handrail clearance needs to be adjusted. 9/27/2024 |
09/27/2024 | COT - RSEL - Outdoor Lighting | N/A | Re-inspection required | Master bath needs shower head and faucet. Exhaust fans need covers in up stairs baths. Second bedroom has a buried receptacle. 9/27/2024 |
09/27/2024 | COT - RSME - Mechanical Final | N/A | Re-inspection required | Master bath needs shower head and faucet. Exhaust fans need covers in up stairs baths. Second bedroom has a buried receptacle. 9/27/2024 |
09/27/2024 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | Master bath needs shower head and faucet. Exhaust fans need covers in up stairs baths. Second bedroom has a buried receptacle. 9/27/2024 |
09/27/2024 | RSBU - Building Final | N/A | Re-inspection required | Master bath needs shower head and faucet. Exhaust fans need covers in up stairs baths. Second bedroom has a buried receptacle. 9/27/2024 |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-1023-01700
Permit Description: Eisenhower Model Plan La Escalera
Total Completed Inspections - 19
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/28/2024 | COT - RSEL - Electrical Underground | Passed | ||
03/28/2024 | COT - RSPL - Rough Soil | Passed | ||
04/15/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
04/15/2024 | COT - RSBU - Preslab | Passed | ||
05/03/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | All masa clips are properly secured to bottom plate. All j-bolts have a washer and nut tighten to bottom plate. Shear wall anchors are properly installed and secured to bottom plate. Straps are secured on large headers above doors and windows. Okay to proceed with other work | |
05/03/2024 | COT - RSBU - Roof Nailing | Passed | Roof trusses are properly secured to top plate with H2.5 clips. Plywood sheathing is properly nailed to trusses per code. All rat runs and cross bracing is installed per truss calcs. Okay to proceed with top out of plumbing. | |
05/03/2024 | COT - RSEL - Grounding/Bonding | Passed | Ufer ground is in place. | |
07/01/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Approved per Ralph Mellecker. 7/1/2024 | |
07/03/2024 | COT - RSBU - Interior Shear Bracing | Passed | 7/3/24: Shear walls are properly screwed per plan requirements. Okay to proceed with tape, texture, and paint. | |
08/16/2024 | BULD - Electrical Clearance | Passed | Okay to install meter and energize panel. ECO Clearance issued for 7439 E Keller Lane to TEP. | |
08/16/2024 | COT - RSPL - Yard Water Line | Passed | Main water line is connected to meter and under street pressure. | |
08/22/2024 | COT - RSPL - Sewer | Passed | ||
09/13/2024 | RSBU - Building Progress | Passed | Contractor has opened up walls in garage at water supply line, plumber has installed 18+ inches of copper pipes from pex line to first solder joint to meet install requirements. | |
09/27/2024 | ENGR Engineering Final | Passed | CO ready | |
09/30/2024 | COT - RSEL - Electrical Final | Passed | 9/30/24: Plumbing and mechanical issues have been corrected, plans do not show receptacles in 2nd bedroom near entrance. Construction is complete per plans. Okay to issue CERTIFICATE OF OCCUPANCY. | |
09/30/2024 | COT - RSEL - Outdoor Lighting | Passed | 9/30/24: Outdoor lighting is properly installed per plan and city guidelines. | |
09/30/2024 | COT - RSME - Mechanical Final | Passed | 9/30/24: Plumbing and mechanical issues have been corrected, plans do not show receptacles in 2nd bedroom near entrance. Construction is complete per plans. Okay to issue CERTIFICATE OF OCCUPANCY. | |
09/30/2024 | COT - RSPL - Plumbing Final | Passed | 9/30/24: Plumbing and mechanical issues have been corrected, plans do not show receptacles in 2nd bedroom near entrance. Construction is complete per plans. Okay to issue CERTIFICATE OF OCCUPANCY. | |
09/30/2024 | RSBU - Building Final | Passed | 9/30/24: Plumbing and mechanical issues have been corrected, plans do not show receptacles in 2nd bedroom near entrance. Construction is complete per plans. Okay to issue CERTIFICATE OF OCCUPANCY. |