Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Model Building Permit
Apply Date:
11/30/2023
Applicant:
Celina Rodriguez
Description:
SFR BT1383-130 T22-M0014

Permit Reviews

Permit Number - TC-MDP-1023-01657
Permit Status: Inspections complete
Permit Description: SFR BT1383-130 T22-M0014
Start Date Submittal Complete Date Status  
12/01/2023 SITE FROM MODEL PERMIT - PRODUCTION v.1 12/07/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-1023-01657
Permit Status: Inspections complete
Permit Description: SFR BT1383-130 T22-M0014
Total Outstanding Activity Conditions - 4
Date Name
12/01/2023 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
12/01/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
12/01/2023 Post-Tension Inspection Report is required.
12/01/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-MDP-1023-01657
Permit Status: Inspections complete
Permit Description: SFR BT1383-130 T22-M0014
Date Description Comments
10/19/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-1023-01657
Permit Description: SFR BT1383-130 T22-M0014
Total Completed Inspections - 22
Date Description Inspector Results Comments
12/29/2023 COT - RSPL - Yard Water Line Passed Main water line is connected to main water meter and under city's water pressure. Okay to shade pipe and backfill trench.
12/29/2023 COT - RSPL - Sewer Passed Sewer line is connected to underground plumbing and being water tested with no leaks. Okay to shade pipes and backfill trenches.
12/29/2023 COT - RSPL - Backwater Valve Passed Backwater valve is installed between clean outs. Okay to shade pipe and backfill trench.
12/29/2023 COT - RSPL - Rough Soil Passed Underground plumbing is connected to main sewer line and under a water test with no leaks. Okay to shade pipe and backfill trenches.
01/09/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
01/09/2024 COT - RSBU - Preslab Passed
01/09/2024 COT - RSEL - Electrical Underground Passed
01/09/2024 COT - RSEL - Grounding/Bonding Passed
01/19/2024 COT - RSBU - Roof Nailing Passed
01/22/2024 COT - RSBU - Exterior Clips/Sheathing Passed
03/01/2024 BULD - Electrical Clearance Passed TEP ECO
03/07/2024 COT - RSPL - Gas Pressure Test Passed
03/11/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
04/03/2024 COT - RSBU - Interior Shear Bracing Passed
05/08/2024 COT - BULD - SWG Clearance Passed Shut off valves are installed for gas water heater, clothes dryer, and kitchen stove. Okay to supply gas to home. SWG Clearance issued for turn on of gas.
06/06/2024 COT - RSEL - Electrical Final Passed
06/06/2024 COT - RSEL - Outdoor Lighting Passed
06/06/2024 COT - RSME - Mechanical Final Passed
06/06/2024 COT - RSPL - Plumbing Final Passed
06/06/2024 ENGR Engineering Final Passed
06/06/2024 RSBU - Building Final Passed
06/06/2024 RSBU - Building Progress Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
BELLA TIERRA 90 SIC-2023-11-30_V1.PDF DOCUMENTS VIEW
BELLA TIERRA PHASE 1 - LOT 90 START_V1.PDF DOCUMENTS VIEW