Permit: TC-MDP-0925-00541
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
3641 E NEBRASKA SV
Address NEW:
3641 E NEBRASKA SV
Apply Date:
09/29/2025
Applicant:
Description:
Roca Realty model L 1-12 (Model master plan TC-MDP-0723-01248)
Permit Reviews
Permit Number - TC-MDP-0925-00541
Permit Status: Inspections
Permit Description: Roca Realty model L 1-12 (Model master plan TC-MDP-0723-01248)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/02/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 10/15/2025 | REQUIRES RESUBMIT |
| 10/17/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 | 10/31/2025 | APPROVED |
| 10/31/2025 | RESTAMP - RESIDENTIAL v.1 | 11/05/2025 | APPROVED |
Conditions
Permit Number - TC-MDP-0925-00541
Permit Status: Inspections
Permit Description: Roca Realty model L 1-12 (Model master plan TC-MDP-0723-01248)
| Date | Description | Comments |
|---|---|---|
| 09/08/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 09/08/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ | |
| 09/08/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0925-00541
Permit Description: Roca Realty model L 1-12 (Model master plan TC-MDP-0723-01248)
Total Completed Inspections - 11
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/07/2026 | COT - RSPL - Rough Soil | Passed | Okay to backfill. Shading required. 4/7/2026 | |
| 04/15/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 04/15/2026 Approved per plan and reinforcement. Okay to pour. |
|
| 04/15/2026 | COT - RSBU - Preslab | Passed | 04/15/2026 Approved per plan and reinforcement. Okay to pour. |
|
| 04/27/2026 | COT - RSPL - Sewer | Passed | 04/27/2026 Approved per plan. Holding under test to private septic system with green tracer wire, ok to backfill with shading material. |
|
| 05/20/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 05/20/2026 | COT - RSBU - Roof Nailing | Passed | ||
| 06/10/2026 | COT - RSEL - Grounding/Bonding | Passed | ||
| 06/30/2026 | COT - RSEL - Electrical Underground | Passed | 06/30/2026 2.5" sch 40 conduit run from riser to transformer. Okay to backfill. |
|
| 06/30/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 06/30/2026 Verified added blocking to air register in bedroom, moved smoke detector 3' away from supply vent, added support staples to loose Romex in garage near panel entrance. |
|
| 08/04/2026 | BULD - Electrical Clearance | Passed | 08/04/2026 Clearance for TEP ECO. |
|
| 08/04/2026 | COT - RSPL - Yard Water Line | Passed | 08/04/2026 Holding under test. Ok to backfill, shading required. |