Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0924-01149
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
12814 E TORTOISE POINTE DR
Address NEW:
12814 E TORTOISE POINTE DR
Apply Date:
11/05/2024
Applicant:
Description:
SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes (Model master plan TC-MDP-0123-00347)
Permit Reviews
Permit Number - TC-MDP-0924-01149
Permit Status: Inspections complete
Permit Description: SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes (Model master plan TC-MDP-0123-00347)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/07/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 11/26/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0924-01149
Permit Status: Inspections complete
Permit Description: SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes (Model master plan TC-MDP-0123-00347)
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 09/30/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
| 11/07/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 11/07/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 11/07/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 11/07/2024 | Post-Tension Inspection Report is required. |
| 11/07/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0924-01149
Permit Status: Inspections complete
Permit Description: SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes (Model master plan TC-MDP-0123-00347)
| Date | Description | Comments |
|---|---|---|
| 09/30/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 11/07/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0924-01149
Permite Description: SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes (Model master plan TC-MDP-0123-00347)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/09/2025 | RSBU - Building Final | N/A | Re-inspection required | Driveway is being re done. Label disconnects to identify A/H. Trim plumbing in garage for future use. 5/9/2025 |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0924-01149
Permit Description: SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes (Model master plan TC-MDP-0123-00347)
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/08/2025 | COT - RSPL - Rough Soil | Passed | Piping and setbacks per plan, trench clean with backfill on site. Ok to backfill 1/8/25 | |
| 01/08/2025 | COT - RSPL - Sewer | Passed | Piping and setbacks per plan, trench clean with backfill on site. Ok to backfill | |
| 01/08/2025 | COT - RSPL - Yard Water Line | Passed | Piping and setbacks per plan, trench clean with backfill on site. Ok to backfill 1/8/25 | |
| 01/08/2025 | COT - RSPL - Backwater Valve | Passed | Piping and setbacks per plan, trench clean with backfill on site. Ok to backfill 1/8/25 | |
| 01/22/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 1/22/25 pass | |
| 01/22/2025 | COT - RSEL - Electrical Underground | Passed | 1/22/25 pass | |
| 01/22/2025 | COT - RSEL - Grounding/Bonding | Passed | 1/22/25 pass | |
| 01/23/2025 | COT - RSBU - Preslab | Passed | 1/23/25 pass | |
| 02/20/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 2/20/25 pass | |
| 02/20/2025 | COT - RSBU - Roof Nailing | Passed | 2/20/25 pass | |
| 03/11/2025 | BULD - Electrical Clearance | Passed | 11 Mar 25 TEP CLEARANCE: ECO |
|
| 03/11/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 03/11/2025 | COT - RSPL - Gas Pressure Test | Passed | ||
| 03/25/2025 | COT - RSBU - Interior Shear Bracing | Passed | Passed 3/25/25 ok to tape | |
| 05/05/2025 | COT - BULD - SWG Clearance | Passed | Passed clearance SWG 5/5/25 | |
| 05/09/2025 | COT - RSEL - Outdoor Lighting | Passed | ||
| 05/09/2025 | COT - RSEL - Electrical Final | Passed | ||
| 05/09/2025 | COT - RSME - Mechanical Final | Passed | ||
| 05/09/2025 | COT - RSPL - Plumbing Final | Passed | ||
| 05/09/2025 | RSBU - Building Progress | Passed | ||
| 05/15/2025 | RSBU - Building Final | Passed | 5/15/25 Pass |
|
| 05/15/2025 | ENGR Engineering Final | Passed | Site is in accordance with approved plans. CofO ready. |