Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Model Building Permit
Apply Date:
09/19/2024
Applicant:
Varnado Standifer
Description:
Blackhawk - T698 - Layla

Permit Reviews

Permit Number - TC-MDP-0924-01100
Permit Status: Inspections
Permit Description: Blackhawk - T698 - Layla
Start Date Submittal Complete Date Status  
09/24/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 10/01/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0924-01100
Permit Status: Inspections
Permit Description: Blackhawk - T698 - Layla
Total Outstanding Activity Conditions - 5
Date Name
09/20/2024 Post-Tension Inspection Report is required.
09/20/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
09/26/2024 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
09/26/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
09/26/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Conditions

Permit Number - TC-MDP-0924-01100
Permit Status: Inspections
Permit Description: Blackhawk - T698 - Layla
Date Description Comments
10/01/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
09/20/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
09/26/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0924-01100
Permit Description: Blackhawk - T698 - Layla
Total Completed Inspections - 7
Date Description Inspector Results Comments
11/13/2024 COT - RSPL - Rough Soil Passed 11-13-24, underground plumbing, setbacks,main water line, backflow valve, & electrical underground all verified as per approved plans. Okay to backfill-provide shading.
11/13/2024 COT - RSPL - Backwater Valve Passed 11-13-24, underground plumbing, setbacks,main water line, backflow valve, & electrical underground all verified as per approved plans. Okay to backfill-provide shading.
11/13/2024 COT - RSPL - Sewer Passed 11-13-24, underground plumbing, setbacks,main water line, sewer connection,backflow valve, & electrical underground all verified as per approved plans. Okay to backfill-provide shading.
11/13/2024 COT - RSPL - Yard Water Line Passed 11-13-24, underground plumbing, setbacks,main water line, backflow valve, & electrical underground all verified as per approved plans. Okay to backfill-provide shading.
11/19/2024 COT - RSBU - Preslab Passed 11-19-24, preslab verified as per approved plans. Okay to pour concrete.
11/19/2024 COT - RSEL - Electrical Underground Passed 11-19-24, excavation/rebar/zoning ,ufer,verified as per approved plans. Okay to pour concrete.
11/19/2024 COT - RSBU - Excavation/Rebar/Zoning Passed 11-19-24, excavation/rebar/zoning verified as per approved plans. Okay to pour concrete.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
BLACKHAWK RANCH LOT 74 START-REV1 09.17.24_V1.PDF DOCUMENTS VIEW
TC-MDP-0923-01492 BLACKHAWK- T698_SIC - LOT 74_6086 E CAMPOLINA TR-2024-09-20_V1.PDF DOCUMENTS VIEW