Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Model Building Permit
Apply Date:
10/08/2024
Applicant:
Dana Petty
Description:
SFR MER1402190 T21-M0078 (Model master plan TC-MDP-0223-00502) REV1: Revised plans to show the alternate AC location.

Permit Reviews

Permit Number - TC-MDP-0924-01038
Permit Status: Issued
Permit Description: SFR MER1402190 T21-M0078 (Model master plan TC-MDP-0223-00502) REV1: Revised plans to show the alternate AC location.
Start Date Submittal Complete Date Status  
01/30/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 02/03/2025 APPROVED Review Details
10/10/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 10/11/2024 APPROVED Review Details
01/03/2025 SITE FROM MODEL PERMIT - PRODUCTION REVISION v.1 01/10/2025 APPROVED Review Details

Conditions

Permit Number - TC-MDP-0924-01038
Permit Status: Issued
Permit Description: SFR MER1402190 T21-M0078 (Model master plan TC-MDP-0223-00502) REV1: Revised plans to show the alternate AC location.
Date Description Comments
10/11/2024 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
10/10/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
10/11/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
01/31/2025 Post-Installed Anchor Inspection Report is required.
10/11/2024 Post-Tension Inspection Report is required.
09/19/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
09/19/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
10/11/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-MDP-0924-01038
Permite Description: SFR MER1402190 T21-M0078 (Model master plan TC-MDP-0223-00502) REV1: Revised plans to show the alternate AC location.
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
12/26/2024 COT - RSBU - Exterior Clips/Sheathing N/A Canceled 12-26-24, canceled by contractor.
12/26/2024 COT - RSBU - Roof Nailing N/A Canceled 12-26-24, canceled by contractor.

Completed Inspections

Permit Status: Issued
Permit Number: TC-MDP-0924-01038
Permit Description: SFR MER1402190 T21-M0078 (Model master plan TC-MDP-0223-00502) REV1: Revised plans to show the alternate AC location.
Total Completed Inspections - 13
Date Description Inspector Results Comments
12/04/2024 COT - RSPL - Backwater Valve Passed Underground plumbing is complete, double clean out is installed with backwater valve in place, all piping is connected to main sewer line with green tracer wire in place and entire system is under a water pressure test. Okay to shade pipes and backfill trenches.
12/04/2024 COT - RSPL - Rough Soil Passed Underground plumbing is complete, double clean out is installed with backwater valve in place, all piping is connected to main sewer line with green tracer wire in place and entire system is under a water pressure test. Okay to shade pipes and backfill trenches.
12/04/2024 COT - RSPL - Sewer Passed Underground plumbing is complete, double clean out is installed with backwater valve in place, all piping is connected to main sewer line with green tracer wire in place and entire system is under a water pressure test. Okay to shade pipes and backfill trenches.
12/04/2024 COT - RSPL - Yard Water Line Passed Main water supply line is connected at street to main city meter and under street pressure with no leaks. Okay to shade pipe and backfill trench.
12/11/2024 COT - RSBU - Excavation/Rebar/Zoning Passed 12-11-24, setbacks,electrical underground, bonding/grounding, preslab per approved plans. Okay to pour concrete.
12/11/2024 COT - RSBU - Preslab Passed 12-11-24, setbacks,electrical underground, bonding/grounding, preslab per approved plans. Okay to pour concrete.
12/11/2024 COT - RSEL - Grounding/Bonding Passed 12-11-24, electrical underground, bonding/grounding, preslab per approved plans. Okay to pour concrete.
12/11/2024 COT - RSEL - Electrical Underground Passed 12-11-24, electrical underground, bonding/grounding, preslab per approved plans. Okay to pour concrete.
12/27/2024 COT - RSBU - Exterior Clips/Sheathing Passed 12/27/24 missing anchor bolts in a few places. Ok to proceed;
12/27/2024 COT - RSBU - Roof Nailing Passed 12/27/24 missing anchor bolts in a few places. Ok to proceed;
01/22/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed with corrections
01/28/2025 BULD - Electrical Clearance Passed 1-28-25, panel approved to energized. ECO clearance sent to TEP
01/28/2025 COT - RSPL - Gas Pressure Test Passed 1-28-25, gas pressure test approved.

Documents

File Name Document Type  
152204 PT LOT 147 COMPLETE-2025-01-27_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LOT 147 PLOT PLAN REVISION1_V1.PDF DOCUMENTS VIEW
PERMIT TC-MDP-0924-01038 12.30.24_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LOT 147 PLOT PLAN_V1.PDF DOCUMENTS VIEW
LOT 147 SPECIAL INSPECTION CERTIFICATE-2024-10-08_V1.PDF DOCUMENTS VIEW