Permit: TC-MDP-0824-00853
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
3003 N SIBLEY MINE RD
Address NEW:
3003 N SIBLEY MINE RD
Apply Date:
08/05/2024
Applicant:
Description:
SFR K35L T21-M0035
Permit Reviews
Permit Number - TC-MDP-0824-00853
Permit Status: Inspections complete
Permit Description: SFR K35L T21-M0035
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/09/2024 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 08/15/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0824-00853
Permit Status: Inspections complete
Permit Description: SFR K35L T21-M0035
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 08/08/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
| 08/15/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 08/15/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 08/15/2024 | Post-Tension Inspection Report is required. |
Conditions
Permit Number - TC-MDP-0824-00853
Permit Status: Inspections complete
Permit Description: SFR K35L T21-M0035
| Date | Description | Comments |
|---|---|---|
| 08/08/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 08/15/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0824-00853
Permite Description: SFR K35L T21-M0035
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/23/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 9/23/24: Anchor bolt spacing greater than 6' on west and east wall. Interior shot pins must be spaced 36" on center. Shear wall at garage require 2 anchor bolts, |
| 10/24/2024 | BULD - Electrical Clearance | N/A | Not Ready | Loose UFER bond |
| 10/24/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Not Ready | Electrical not per plan, no block on register box, fire block missing at 1in pex, fire foam missing in several places, pex line on gusset, nail plates on island loose |
| 10/24/2024 | COT - RSEL - Grounding/Bonding | N/A | Not Ready | loose connection to rebar |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0824-00853
Permit Description: SFR K35L T21-M0035
Total Completed Inspections - 21