Permit: TC-MDP-0823-01466
Permit Details
Apply Date:
09/21/2023
Applicant:
Andrea Flood
Description:
SFR F40F22 T22-M0026
Permit Reviews
Permit Number - TC-MDP-0823-01466
Permit Status: Issued
Permit Description: SFR F40F22 T22-M0026
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/22/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 09/25/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0823-01466
Permit Status: Issued
Permit Description: SFR F40F22 T22-M0026
Total Outstanding Activity Conditions - 7
Date | Name |
---|---|
07/20/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
09/22/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
09/22/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
09/22/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
09/22/2023 | Post-Tension Inspection Report is required. |
09/22/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
09/22/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-0823-01466
Permit Status: Issued
Permit Description: SFR F40F22 T22-M0026
Date | Description | Comments |
---|---|---|
07/20/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
08/01/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-MDP-0823-01466
Permite Description: SFR F40F22 T22-M0026
Total Outstanding Inspections - 3
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/12/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | Seal penetrations of vapor barrier at garage by WH, complete wiring in kitchen by range, complete wiring for great room floor, electrical not per plans. Plans call for great room, Bed. 2 and flex room to be 20amp 12 gauge wire. Not 15amp 14 gauge wire., plumbing not per plans. Missing cleanouts at bathrooms, throughout. |
04/23/2024 | RSBU - Building Progress | N/A | Not Applicable | |
04/23/2024 | ENGR Engineering Final | N/A | Partial Pass | Landscaping is not complete on the east side of the building the gates not in, and there’s a pizza sidewalk on that same size that needs to be poured |
Completed Inspections
Permit Status: Issued
Permit Number: TC-MDP-0823-01466
Permit Description: SFR F40F22 T22-M0026
Total Completed Inspections - 19