Permit: TC-MDP-0823-01444
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
10050 S ARNOLD RANCH CT
Address NEW:
10050 S ARNOLD RANCH CT
Apply Date:
08/18/2023
Applicant:
Description:
SFR K35I T21-M0034
Permit Reviews
Permit Number - TC-MDP-0823-01444
Permit Status: Inspections complete
Permit Description: SFR K35I T21-M0034
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/19/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 08/23/2023 | APPROVED |
| 01/29/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 01/29/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0823-01444
Permit Status: Inspections complete
Permit Description: SFR K35I T21-M0034
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 08/19/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 08/19/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 08/19/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 08/19/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
| 08/22/2023 | Post-Tension Inspection Report is required. |
| 08/22/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-0823-01444
Permit Status: Inspections complete
Permit Description: SFR K35I T21-M0034
| Date | Description | Comments |
|---|---|---|
| 08/18/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0823-01444
Permit Description: SFR K35I T21-M0034
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/21/2024 | COT - RSPL - Rough Soil | Passed | ||
| 02/21/2024 | COT - RSPL - Sewer | Passed | ||
| 02/21/2024 | COT - RSPL - Yard Water Line | Passed | ||
| 03/05/2024 | COT - RSBU - Preslab | Passed | ||
| 03/05/2024 | COT - RSEL - Electrical Underground | Passed | ||
| 03/05/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
| 03/25/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | All clips are installed and properly nailed to the studs, rafters, and top plates. Exterior and interior shear walls are properly sheathed and nailed per plans. All base plates are properly shot down or bolted to the floor. Okay to proceed with dry in of exterior walls. | |
| 03/25/2024 | COT - RSBU - Roof Nailing | Passed | Roof sheathing is properly nailed off. All rafters have H2.5 clips attached to rafter and top plate. Facia board and drip cap are properly nailed to end of rafters. Okay to proceed with dry-in of roof. | |
| 04/19/2024 | BULD - Electrical Clearance | Passed | TEP Clearance given for ECO at 10050 S Arnold Ranch Ct. | |
| 04/19/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with installation of insulation and drywall. | |
| 04/19/2024 | COT - RSPL - Gas Pressure Test | Passed | Gas line is holding 15# of air pressure. Okay to proceed with installation of insulation and drywall. | |
| 04/19/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Passed 3-5-24 by E. Adams. | |
| 05/02/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 06/17/2024 | COT - BULD - SWG Clearance | Passed | Gas valves are installed in laundry room, kitchen, and garage for all gas appliances. SWG Clearance issued for this unit. | |
| 07/01/2024 | RSBU - Building Final | Passed | ||
| 07/01/2024 | ENGR Engineering Final | Passed | ||
| 07/01/2024 | COT - RSPL - Plumbing Final | Passed | ||
| 07/01/2024 | COT - RSME - Mechanical Final | Passed | ||
| 07/01/2024 | COT - RSEL - Outdoor Lighting | Passed | ||
| 07/01/2024 | COT - RSEL - Electrical Final | Passed | ||
| 07/01/2024 | RSBU - Building Progress | Passed |