Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0724-00817
Permit Details
Apply Date:
10/31/2024
Applicant:
Celina Rodriguez
Description:
Bella Tierra Phase 3 1745-130 (Model Master Plan TC-MDP-0823-01363)
Permit Reviews
Permit Number - TC-MDP-0724-00817
Permit Status: Inspections
Permit Description: Bella Tierra Phase 3 1745-130 (Model Master Plan TC-MDP-0823-01363)
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/31/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 10/31/2024 | REQUIRES RESUBMIT |
11/07/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.2 | 11/18/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0724-00817
Permit Status: Inspections
Permit Description: Bella Tierra Phase 3 1745-130 (Model Master Plan TC-MDP-0823-01363)
Total Outstanding Activity Conditions - 4
Date | Name |
---|---|
07/25/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
11/07/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
11/07/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
11/07/2024 | Post-Tension Inspection Report is required. |
Conditions
Permit Number - TC-MDP-0724-00817
Permit Status: Inspections
Permit Description: Bella Tierra Phase 3 1745-130 (Model Master Plan TC-MDP-0823-01363)
Date | Description | Comments |
---|---|---|
07/25/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0724-00817
Permite Description: Bella Tierra Phase 3 1745-130 (Model Master Plan TC-MDP-0823-01363)
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/27/2024 | COT - RSEL - Grounding/Bonding | N/A | Partial Pass | Concrete forms are set, post tension cabling is in place and properly spaced, masa clips and shear wall hold downs are installed on forms as required, underground plumbing pipes are properly wrapped with foam, underground electrical for kitchen island is installed, and Ufer ground is in place on transformer side of garage. Okay to pour concrete. |
01/24/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 1/24/25 missing register on flex in back bathroom, seal penetrations on rear wall by PEX tubing. Fire blocking required at all penetrations at top plates. re inspection required. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0724-00817
Permit Description: Bella Tierra Phase 3 1745-130 (Model Master Plan TC-MDP-0823-01363)
Total Completed Inspections - 11
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/21/2024 | COT - RSPL - Yard Water Line | Passed | Water line on 60psi air test. Okay to backfill. Shading required. 11/21/2024 | |
11/22/2024 | COT - RSPL - Rough Soil | Passed | 11/22/24: stack is top out with water, big rocks have been removed from trenches. underground plumbing is connected to main sewer line. Okay to shade pipe and backfill trenches. | |
11/22/2024 | COT - RSPL - Sewer | Passed | 11/22/24: stack is top out with water, big rocks have been removed from trenches. underground plumbing is connected to main sewer line. Okay to shade pipe and backfill trenches. | |
11/27/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Concrete forms are set, post tension cabling is in place and properly spaced, masa clips and shear wall hold downs are installed on forms as required, underground plumbing pipes are properly wrapped with foam, underground electrical for kitchen island is installed, and Ufer ground is in place on transformer side of garage. Okay to pour concrete. | |
11/27/2024 | COT - RSBU - Preslab | Passed | Concrete forms are set, post tension cabling is in place and properly spaced, masa clips and shear wall hold downs are installed on forms as required, underground plumbing pipes are properly wrapped with foam, underground electrical for kitchen island is installed, and Ufer ground is in place on transformer side of garage. Okay to pour concrete. | |
11/27/2024 | COT - RSEL - Electrical Underground | Passed | Concrete forms are set, post tension cabling is in place and properly spaced, masa clips and shear wall hold downs are installed on forms as required, underground plumbing pipes are properly wrapped with foam, underground electrical for kitchen island is installed, and Ufer ground is in place on transformer side of garage. Okay to pour concrete. | |
12/17/2024 | COT - RSBU - Roof Nailing | Passed | ||
12/20/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | 12/20/24 corrections made | |
01/24/2025 | COT - RSPL - Gas Pressure Test | Passed | 1/24/25 pass | |
01/27/2025 | COT - RSEL - Grounding/Bonding | Passed | 1/27/25 pass | |
01/27/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 1/27/25 pass |