Permit: TC-MDP-0723-01259
Permit Details
Apply Date:
10/31/2023
Applicant:
Stephanie Bebee
Description:
SFR CVPLAN2.5 T22-M0062 V2 Structural changes
Permit Reviews
Permit Number - TC-MDP-0723-01259
Permit Status: Complete
Permit Description: SFR CVPLAN2.5 T22-M0062 V2 Structural changes
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/31/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 11/02/2023 | APPROVED |
06/27/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 06/28/2024 | APPROVED |
02/09/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 02/12/2024 | APPROVED |
Conditions
Permit Number - TC-MDP-0723-01259
Permit Status: Complete
Permit Description: SFR CVPLAN2.5 T22-M0062 V2 Structural changes
Date | Description | Comments |
---|---|---|
10/31/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
06/24/2024 | Post-Tension Inspection Report is required. | |
07/18/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
10/31/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
11/01/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0723-01259
Permite Description: SFR CVPLAN2.5 T22-M0062 V2 Structural changes
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/09/2024 | COT - RSBU - Exterior Clips/Sheathing | N/A | Re-inspection required | 1/9/24: missing nailing at shear wall in garage. Missing anchor bolts at shear wall by powder room. RSP clips missing nailing and missing at exterior. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0723-01259
Permit Description: SFR CVPLAN2.5 T22-M0062 V2 Structural changes
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/17/2023 | COT - RSPL - Yard Water Line | Passed | ||
11/17/2023 | COT - RSPL - Sewer | Passed | ||
11/17/2023 | COT - RSPL - Rough Soil | Passed | ||
11/27/2023 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Rebar reinforcement is in place for shear wall straps. Post tension cabling is in place. | |
11/27/2023 | COT - RSBU - Preslab | Passed | okay to pour concrete slab. | |
11/27/2023 | COT - RSEL - Grounding/Bonding | Passed | Ufer ground is in place, okay to pour concrete. | |
01/09/2024 | COT - RSBU - Roof Nailing | Passed | ||
01/12/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | 1-12-24: Missing nails and anchor bolts have been installed throughout house. | |
03/04/2024 | BULD - Electrical Clearance | Passed | Panel is properly installed and grounded to the Ufer ground. Okay to install meter and energize system. | |
03/12/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
03/13/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 3/13/24: Water supply pex line and DWV are under a pressure test with no leaks. Anchor bolt has been added to shear wall downstairs. Okay to proceed with installation of insulation and drywall. | |
04/22/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
06/14/2024 | COT - BULD - SWG Clearance | Passed | ||
06/18/2024 | COT - RSEL - Electrical Final | Passed | ||
06/18/2024 | COT - RSEL - Electrical Underground | Passed | ||
06/18/2024 | COT - RSEL - Outdoor Lighting | Passed | ||
06/18/2024 | COT - RSME - Mechanical Final | Passed | ||
06/18/2024 | RSBU - Building Progress | Passed | ||
06/20/2024 | COT - RSPL - Plumbing Final | Passed | ||
06/20/2024 | RSBU - Building Final | Passed | ||
06/20/2024 | ENGR Engineering Final | Passed |