Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Model Building Permit
Apply Date:
06/19/2025
Applicant:
Alexander Anderson
Description:
SFR MPLAN1510 (Model master plan TC-MDP-0425-00272)

Permit Reviews

Permit Number - TC-MDP-0625-00373
Permit Status: Issued
Permit Description: SFR MPLAN1510 (Model master plan TC-MDP-0425-00272)
Start Date Submittal Complete Date Status  
09/19/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 09/19/2025 REQUIRES RESUBMIT Review Details
09/22/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.3 09/22/2025 APPROVED Review Details
07/11/2025 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 07/11/2025 APPROVED Review Details
06/23/2025 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 07/08/2025 REQUIRES RESUBMIT Review Details
07/11/2025 RESTAMP - RESIDENTIAL v.1 07/18/2025 APPROVED Review Details
09/22/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.2 09/22/2025 REQUIRES RESUBMIT Review Details
07/24/2025 SITE FROM MODEL TEMPLATE INFILL BUILDERS REVISION v.1 08/08/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0625-00373
Permit Status: Issued
Permit Description: SFR MPLAN1510 (Model master plan TC-MDP-0425-00272)
Total Outstanding Activity Conditions - 1
Date Name
06/23/2025 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/

Conditions

Permit Number - TC-MDP-0625-00373
Permit Status: Issued
Permit Description: SFR MPLAN1510 (Model master plan TC-MDP-0425-00272)
Date Description Comments
06/23/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
06/23/2025 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
06/23/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
09/22/2025 SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED.
07/03/2025 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-MDP-0625-00373
Permite Description: SFR MPLAN1510 (Model master plan TC-MDP-0425-00272)
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
09/03/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Partial Pass 9.3.2025
Partial pending 3x nails every 16" on second floor sole plate as marked, add h2.5 as marked in garage, add hangers on north wall overhang.
10/01/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required Plumbing leak at upstairs toilet, some electrical work incomplete
09/03/2025 COT - RSBU - Interior Shear Bracing N/A Not Ready 9.3.2025
Not ready, use for fire wall.
08/08/2025 COT - RSPL - Yard Water Line N/A Partial Pass 8.8.2025
Partial pass pending water line needs to be under test.

Completed Inspections

Permit Status: Issued
Permit Number: TC-MDP-0625-00373
Permit Description: SFR MPLAN1510 (Model master plan TC-MDP-0425-00272)
Total Completed Inspections - 15
Date Description Inspector Results Comments
08/08/2025 COT - RSPL - Backwater Valve Passed
08/08/2025 COT - RSPL - Rough Soil Passed 8.8.2025
Plumbing underground approved per plan, okay to proceed with shading.
08/08/2025 COT - RSPL - Sewer Passed
08/18/2025 COT - RSBU - Excavation/Rebar/Zoning Passed
08/18/2025 COT - RSBU - Preslab Passed Ensure slab area is termite treated.
08/18/2025 COT - RSEL - Electrical Underground Passed
08/18/2025 COT - RSEL - Grounding/Bonding Passed
09/03/2025 COT - RSBU - Roof Nailing Passed
09/10/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 9.10.2025
Corrections made to prior 9.3.2025 inspection.
09/24/2025 COT - RSPL - Gas Pressure Test Passed 9-24-25: gas line verified under test at 15psi.
10/01/2025 BULD - Electrical Clearance Passed Passed 10/1/25 CLEARANCE ECO
10/03/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Ok to insulate and sheet rock,throughout
10/30/2025 RSBU - Building Progress Passed
10/30/2025 COT - RSBU - Interior Shear Bracing Passed
10/30/2025 COT - RSPL - Yard Water Line Passed

Documents

File Name Document Type  
FINAL1380_SIC_156469 PT LOT 10 COMPLETE-2025-09-19-2025-09-22_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
1_SC LOT 10 STRUCTURAL CALCS 04.23.25_V1.PDF DOCUMENTS VIEW
CONS-1_D LOT 10 1X CHANGES FINAL SET 07.23.25_V1.PDF DOCUMENTS VIEW
M SENTINEL VISTA LOT 10 MANUAL D_V1.PDF DOCUMENTS VIEW
M SENTINEL VISTA LOT 10 MANUAL J S_V1.PDF DOCUMENTS VIEW
T 1510 L10 TRUSS REVIEW - TRUSS LAYOUT_V1.PDF DOCUMENTS VIEW
T 1510 L10 TRUSSES_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW