Permit: TC-MDP-0625-00344
Permit Details
Apply Date:
07/02/2025
Applicant:
Ramon VALDEZ
Description:
REV1: New Sqft reflects on all lots along with new lot coverage Duplex SFR & ADU (Model master plan TC-MDP-1224-01416)
Permit Reviews
Permit Number - TC-MDP-0625-00344
Permit Status: Inspections
Permit Description: REV1: New Sqft reflects on all lots along with new lot coverage
Duplex SFR & ADU (Model master plan TC-MDP-1224-01416)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/09/2026 | SITE FROM MODEL TEMPLATE INFILL BUILDERS REVISION v.1 | 01/15/2026 | REQUIRES RESUBMIT |
| 12/02/2025 | ADMINISTRATIVE v.2 | 12/02/2025 | APPROVED |
| 09/17/2025 | ADMINISTRATIVE v.1 | 09/17/2025 | REQUIRES RESUBMIT |
| 09/12/2025 | RESTAMP - RESIDENTIAL v.2 | 09/17/2025 | APPROVED |
| 07/24/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 | 08/11/2025 | REQUIRES RESUBMIT |
| 07/21/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 07/22/2026 | APPROVED |
| 09/02/2025 | RESTAMP - RESIDENTIAL v.1 | 09/05/2025 | REQUIRES RESUBMIT |
| 08/15/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.3 | 09/02/2025 | APPROVED |
| 07/03/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 07/22/2025 | REQUIRES RESUBMIT |
| 01/15/2026 | SITE FROM MODEL TEMPLATE INFILL BUILDERS REVISION v.2 | 01/16/2026 | APPROVED |
Conditions
Permit Number - TC-MDP-0625-00344
Permit Status: Inspections
Permit Description: REV1: New Sqft reflects on all lots along with new lot coverage
Duplex SFR & ADU (Model master plan TC-MDP-1224-01416)
| Date | Description | Comments |
|---|---|---|
| 01/12/2026 | Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. | |
| 12/02/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 06/16/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 06/16/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ | |
| 07/17/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. | |
| 12/09/2025 | A Minor Subdivision and Supplemental Site Plan for APN 11811043A, 11811043B, 11811044A, and 11811044B is required to be reviewed and approved by the City of Tucson prior to close out of this building permit |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0625-00344
Permite Description: REV1: New Sqft reflects on all lots along with new lot coverage
Duplex SFR & ADU (Model master plan TC-MDP-1224-01416)
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/21/2026 | COT - RSEL - Grounding/Bonding | N/A | Partial Pass | 4/21/2026 corrections were made. Pending tie into equipment. |
| 07/13/2026 | COT - RSEL - Electrical Underground | N/A | Not Applicable |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0625-00344
Permit Description: REV1: New Sqft reflects on all lots along with new lot coverage
Duplex SFR & ADU (Model master plan TC-MDP-1224-01416)
Total Completed Inspections - 19
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/17/2026 | COT - RSPL - Rough Soil | Passed | Passed 4/17/26 | |
| 04/17/2026 | COT - RSPL - Sewer | Passed | Passed 4/17/26 | |
| 04/21/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 4/21/2026 corrections were made. | |
| 04/21/2026 | COT - RSBU - Preslab | Passed | 4/21/2026 corrections were made. | |
| 05/18/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 05/18/2026 | COT - RSBU - Roof Nailing | Passed | ||
| 05/20/2026 | BULD - Electrical Clearance | Passed | 5-20-26: okay to energize Unit's 1& 2. ECO clearance issued to TEP. | |
| 05/20/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 5-20-26: intermediates approved. Okay to continue with construction. | |
| 05/20/2026 | COT - RSEL - Grounding/Bonding | Passed | 5-20-26: grounding/bonding approved. | |
| 07/13/2026 | COT - RSBU - Firewall/Fire Barrier/Firestop | Passed | ||
| 07/13/2026 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 07/13/2026 | COT - RSEL - Outdoor Lighting | Passed | ||
| 07/13/2026 | COT - RSPL - Yard Water Line | Passed | ||
| 07/14/2026 | COT - RSPL - Plumbing Final | Passed | 7-14-26: plumbing final approved. | |
| 07/14/2026 | COT - RSEL - Electrical Final | Passed | 7-14-26: electrical final approved. | |
| 07/14/2026 | COT - RSME - Mechanical Final | Passed | 7-14-26: mechanical final approved. | |
| 07/14/2026 | RSBU - Building Final | Passed | 7-14-26: building final approved. | |
| 07/21/2026 | LAND Landscape Appearance & Function Final | Passed | ||
| 07/21/2026 | ENGR Engineering Final | Passed |