Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Model Building Permit
Address NEW:
6113 E CAMPOLINA TR
Apply Date:
06/30/2025
Applicant:
Chris Irby
Description:
Blackhawk T934 - Frasier (Model master plan TC-MDP-0923-01490)

Permit Reviews

Permit Number - TC-MDP-0625-00332
Permit Status: Inspections
Permit Description: Blackhawk T934 - Frasier (Model master plan TC-MDP-0923-01490)
Start Date Submittal Complete Date Status  
07/02/2025 SITE FROM MODEL PERMIT - PRODUCTION v.1 07/08/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0625-00332
Permit Status: Inspections
Permit Description: Blackhawk T934 - Frasier (Model master plan TC-MDP-0923-01490)
Total Outstanding Activity Conditions - 4
Date Name
06/11/2025 Post-Tension Inspection Report is required.
06/11/2025 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
07/02/2025 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
07/02/2025 Post-Installed Anchor Inspection Report is required.

Conditions

Permit Number - TC-MDP-0625-00332
Permit Status: Inspections
Permit Description: Blackhawk T934 - Frasier (Model master plan TC-MDP-0923-01490)
Date Description Comments
07/08/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
06/11/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0625-00332
Permite Description: Blackhawk T934 - Frasier (Model master plan TC-MDP-0923-01490)
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
03/18/2026 COT - RSPL - Sewer N/A Re-inspection required 03/18/2026
Plans T936 left on site do not match field assembly. Site plan references plan T934, could not find plans in back office site either.
03/18/2026 COT - RSPL - Rough Soil N/A Re-inspection required 03/18/2026
Plans T936 left on site do not match field assembly. Site plan references plan T934, could not find plans in back office site either.
04/08/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 04/08/2026
Replaced damaged 2x6 stud at front porch column, add anchor bolts at marked locations, add A34 clip to gable end bracing - refer to detail SD1.3b-5. Add second bracing at A2M trusses.
04/08/2026 COT - RSBU - Roof Nailing N/A Re-inspection required 04/08/2026
Replaced damaged 2x6 stud at front porch column, add anchor bolts at marked locations, add A34 clip to gable end bracing - refer to detail SD1.3b-5. Add second bracing at A2M trusses.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0625-00332
Permit Description: Blackhawk T934 - Frasier (Model master plan TC-MDP-0923-01490)
Total Completed Inspections - 7
Date Description Inspector Results Comments
03/18/2026 COT - RSPL - Yard Water Line Passed 03/18/2026
Holding under test from meter. Ok to backfill, shading required.
03/18/2026 COT - RSPL - Sewer Passed 03/18/2026
Verified site plans provided and match field conditions. Okay to backfill. Shading required.
03/18/2026 COT - RSPL - Rough Soil Passed 03/18/2026
Verified site plans provided and match field conditions. Okay to backfill. Shading required.
03/26/2026 COT - RSBU - Excavation/Rebar/Zoning Passed
03/26/2026 COT - RSBU - Preslab Passed approved
03/26/2026 COT - RSEL - Electrical Underground Passed
03/26/2026 COT - RSEL - Grounding/Bonding Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
BLACKHAWK LOT 34 T934_ SIC-6113 S CAMPOLINA TR-2025-06-30_V1.PDF DOCUMENTS VIEW
BLACKHAWK RANCH LOT 34-START_V1.PDF DOCUMENTS VIEW