Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0624-00733
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
12877 E TORTOISE POINTE DR
Address NEW:
12877 E TORTOISE POINTE DR
Apply Date:
08/09/2024
Applicant:
Description:
SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes
Permit Reviews
Permit Number - TC-MDP-0624-00733
Permit Status: Inspections complete
Permit Description: SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/12/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 08/19/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0624-00733
Permit Status: Inspections complete
Permit Description: SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 06/24/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
| 08/19/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 08/19/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 08/19/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 08/19/2024 | Post-Tension Inspection Report is required. |
| 08/19/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0624-00733
Permit Status: Inspections complete
Permit Description: SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes
| Date | Description | Comments |
|---|---|---|
| 06/24/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 08/19/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. | |
| 09/27/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0624-00733
Permit Description: SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/13/2024 | COT - RSPL - Rough Soil | Passed | Underground plumbing is connected to main sewer line and under a water test with no leaks. Okay to shade pipe and backfill trenches. | |
| 09/13/2024 | COT - RSPL - Sewer | Passed | Underground plumbing is connected to main sewer line and under a water test with no leaks. Okay to shade pipe and backfill trenches. | |
| 09/13/2024 | COT - RSPL - Yard Water Line | Passed | Main water line is installed to meter and is under street pressure. Okay to shade pipe and backfill trench. | |
| 09/24/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 09/24/2024 | COT - RSBU - Preslab | Passed | ||
| 09/24/2024 | COT - RSEL - Electrical Underground | Passed | ||
| 09/24/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
| 10/09/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | Okay to proceed with rough-in. | |
| 10/09/2024 | COT - RSBU - Roof Nailing | Passed | Okay to proceed with rough-in. | |
| 12/02/2024 | BULD - Electrical Clearance | Passed | 12-2-24, okay for panel to be energized by TEP (ECO). | |
| 12/02/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 12-2-24, approved. | |
| 12/02/2024 | COT - RSPL - Gas Pressure Test | Passed | 12-2-24, gas pressure test verified and residential intermediates approved. Okay to continue with construction. | |
| 12/27/2024 | COT - RSBU - Interior Shear Bracing | Passed | 12/27/24 passed, ok to tape | |
| 02/13/2025 | COT - BULD - SWG Clearance | Passed | Passed CLEARANCE SWG 2/13/25 | |
| 02/24/2025 | ENGR Engineering Final | Passed | CO Ready | |
| 02/28/2025 | COT - RSEL - Outdoor Lighting | Passed | ||
| 02/28/2025 | COT - RSME - Mechanical Final | Passed | ||
| 02/28/2025 | COT - RSPL - Plumbing Final | Passed | ||
| 02/28/2025 | RSBU - Building Progress | Passed | ||
| 03/05/2025 | COT - RSEL - Electrical Final | Passed | 3/5/25 corrections made | |
| 03/05/2025 | RSBU - Building Final | Passed | 3/5/25 corrections made |