Permit: TC-MDP-0623-01184
Permit Details
Apply Date:
06/23/2023
Applicant:
Andrea Flood
Description:
SFR F40G22 T22-M0025 Revision-Truss Calcs
Permit Reviews
Permit Number - TC-MDP-0623-01184
Permit Status: Complete
Permit Description: SFR F40G22 T22-M0025 Revision-Truss Calcs
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/28/2023 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 10/02/2023 | APPROVED |
06/27/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 06/28/2023 | APPROVED |
Conditions
Permit Number - TC-MDP-0623-01184
Permit Status: Complete
Permit Description: SFR F40G22 T22-M0025 Revision-Truss Calcs
Date | Description | Comments |
---|---|---|
06/27/2023 | Applies to All: Deferred submittal documents must be submitted and approved prior to installation of construction elements included in deferred submittal documents. | |
06/27/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
06/27/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
06/27/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
10/02/2023 | Post-Tension Inspection Report is required. | |
06/27/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
06/27/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
06/27/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
06/27/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0623-01184
Permite Description: SFR F40G22 T22-M0025 Revision-Truss Calcs
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/28/2023 | COT - RSBU - Exterior Clips/Sheathing | N/A | Partial Pass | Shear wall and back of house missing anchor bolts, remove nails from h2.5 clips on all load bearing walls to allow deflection. |
COT - RSPL - Gas Pressure Test | N/A | Requested |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0623-01184
Permit Description: SFR F40G22 T22-M0025 Revision-Truss Calcs
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/26/2023 | COT - RSPL - Sewer | Passed | ||
07/26/2023 | COT - RSPL - Rough Soil | Passed | ||
08/01/2023 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
08/01/2023 | COT - RSBU - Preslab | Passed | ||
08/01/2023 | COT - RSEL - Electrical Underground | Passed | ||
08/01/2023 | COT - RSEL - Grounding/Bonding | Passed | ||
08/28/2023 | COT - RSBU - Roof Nailing | Passed | ||
08/28/2023 | COT - RSPL - Backwater Valve | Passed | ||
09/25/2023 | COT - RSBU - Exterior Clips/Sheathing | Passed | ||
09/25/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
09/25/2023 | BULD - Electrical Clearance | Passed | TEP ECO | |
10/20/2023 | COT - RSBU - Interior Shear Bracing | Passed | ||
10/20/2023 | COT - RSPL - Yard Water Line | Passed | ||
12/06/2023 | COT - BULD - SWG Clearance | Passed | SWG clearance issued. | |
01/08/2024 | COT - RSEL - Electrical Final | Passed | Construction is complete. Mechanical, electrical, and plumbing fixtures. GFCI outlets are installed in kitchen, bathrooms, & garage. Electrical panel is properly labeled. | |
01/08/2024 | COT - RSEL - Outdoor Lighting | Passed | Exterior lights match was called out on plans and are fully operational. | |
01/08/2024 | COT - RSME - Mechanical Final | Passed | Construction is complete. Mechanical, electrical, and plumbing fixtures. GFCI outlets are installed in kitchen, bathrooms, & garage. Electrical panel is properly labeled. | |
01/08/2024 | COT - RSPL - Plumbing Final | Passed | Construction is complete. Mechanical, electrical, and plumbing fixtures. GFCI outlets are installed in kitchen, bathrooms, & garage. Electrical panel is properly labeled. | |
01/08/2024 | RSBU - Building Final | Passed | Construction is complete. Mechanical, electrical, and plumbing fixtures. GFCI outlets are installed in kitchen, bathrooms, & garage. Electrical panel is properly labeled. | |
01/08/2024 | RSBU - Building Progress | Passed | 1-8-24: Construction is complete. Mechanical, electrical, and plumbing fixtures. GFCI outlets are installed in kitchen, bathrooms, & garage. Electrical panel is properly labeled. | |
01/08/2024 | ENGR Engineering Final | Passed |