Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Model Building Permit
Address NEW:
10575 E FOX COVE PL
Apply Date:
08/09/2024
Applicant:
Dana Petty
Description:
SFR MER1502320 T21-M0070 REV1 roof covering change

Permit Reviews

Permit Number - TC-MDP-0524-00551
Permit Status: Complete
Permit Description: SFR MER1502320 T21-M0070 REV1 roof covering change
Start Date Submittal Complete Date Status  
11/07/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 11/08/2024 APPROVED Review Details
08/12/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 08/19/2024 APPROVED Review Details
03/21/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 03/21/2025 APPROVED Review Details

Conditions

Permit Number - TC-MDP-0524-00551
Permit Status: Complete
Permit Description: SFR MER1502320 T21-M0070 REV1 roof covering change
Date Description Comments
08/19/2024 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
08/19/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
08/19/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
08/19/2024 Post-Tension Inspection Report is required.
05/01/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
05/01/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
08/19/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-MDP-0524-00551
Permite Description: SFR MER1502320 T21-M0070 REV1 roof covering change
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/27/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 1-MASA straps have more than one in three legs up. 2-Back columns are not secured to concrete.

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-0524-00551
Permit Description: SFR MER1502320 T21-M0070 REV1 roof covering change
Total Completed Inspections - 21
Date Description Inspector Results Comments
09/04/2024 COT - RSPL - Yard Water Line Passed Main water line is installed and connected to main water supply line and is under street pressure.
09/04/2024 COT - RSPL - Sewer Passed
09/04/2024 COT - RSPL - Rough Soil Passed Underground plumbing is connected to main sewer line and fully under a water test with no leaks. Okay to shade pipes and backfill trenches.
09/11/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
09/11/2024 COT - RSBU - Preslab Passed
09/13/2024 RSBU - Building Progress Passed
09/13/2024 COT - RSEL - Electrical Underground Passed
09/13/2024 COT - RSEL - Grounding/Bonding Passed
09/28/2024 COT - RSBU - Roof Nailing Passed
10/03/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
10/21/2024 BULD - Electrical Clearance Passed
10/21/2024 COT - RSPL - Gas Pressure Test Passed
11/20/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 11/20/24; Letter has been sent to city from architect about electrical wiring. Okay to proceed at own risk hoping electrical is approved
12/11/2024 COT - RSBU - Interior Shear Bracing Passed 12-11-24, interior shear bracing approved plans prior. okay to tape and texture
02/10/2025 COT - BULD - SWG Clearance Passed Pressure testing is complete and passed, sediment traps are installed on water heater, and gas valves are properly installed at gas appliance locations. SWG clearance issued for 10575 E Fox Cove Pl.
02/14/2025 COT - RSEL - Electrical Final Passed Construction is completed. All mechanical, electrical, and plumbing fixtures are installed and fully functional. Okay to issue Certificate of Occupancy.
02/14/2025 COT - RSEL - Outdoor Lighting Passed Construction is completed. All mechanical, electrical, and plumbing fixtures are installed and fully functional. Okay to issue Certificate of Occupancy.
02/14/2025 COT - RSME - Mechanical Final Passed Construction is completed. All mechanical, electrical, and plumbing fixtures are installed and fully functional. Okay to issue Certificate of Occupancy.
02/14/2025 COT - RSPL - Plumbing Final Passed Construction is completed. All mechanical, electrical, and plumbing fixtures are installed and fully functional. Okay to issue Certificate of Occupancy.
02/14/2025 RSBU - Building Final Passed Construction is completed. All mechanical, electrical, and plumbing fixtures are installed and fully functional. Okay to issue Certificate of Occupancy.
02/21/2025 ENGR Engineering Final Passed Site is clean and looks good.

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
150112 PT LOT 69 COMPLETE-2024-11-06_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LOT 69 PLOT PLAN_V1.PDF DOCUMENTS VIEW
LOT 69 SPECIAL INSPECTION CERTIFICATE-2024-08-09_V1.PDF DOCUMENTS VIEW