Permit: TC-MDP-0523-01076
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
12797 E LAZY J RANCH PL
Address NEW:
12797 E LAZY J RANCH PL
Apply Date:
06/08/2023
Applicant:
Amy Stokes, Operations Accountant
Description:
SFR RKM45R T21-M0093 (REVISION 2 Updated Structural cals and pages)
Permit Reviews
Permit Number - TC-MDP-0523-01076
Permit Status: Inspections complete
Permit Description: SFR RKM45R T21-M0093 (REVISION 2 Updated Structural cals and pages)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/30/2023 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 10/30/2023 | APPROVED |
| 06/08/2023 | ZZZMODEL PERMIT REVIEW RESIDENTIAL v.1 | 06/12/2023 | APPROVED |
Conditions
Permit Number - TC-MDP-0523-01076
Permit Status: Inspections complete
Permit Description: SFR RKM45R T21-M0093 (REVISION 2 Updated Structural cals and pages)
| Date | Description | Comments |
|---|---|---|
| 06/10/2023 | Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents. | |
| 06/08/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
| 06/08/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 10/30/2023 | ISSUED WITH PDEQ CONDITIONS: NO FINAL AND NO CERTIFICATE OF OCCUPANCY UNTIL THE PRIVATE SEWER #P21SD00033 IS ISSUED A DISCHARGE AUTHORIZATION BY PDEQ | |
| 06/08/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 10/30/2023 | Post-Tension Inspection Report is required. | |
| 06/09/2023 | A separate building permit for the retaining wall must be issued before finalization of this permit. | |
| 05/25/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 06/08/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
| 06/10/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0523-01076
Permite Description: SFR RKM45R T21-M0093 (REVISION 2 Updated Structural cals and pages)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/25/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | support duct register in bathroom, smoke detector in front of laundry must be 3’ away from duct registers, bang plate needed for dryer vent, support gas line in laundry, correctly install bang plate for laundry vent to right of dryer, flu pipe for furnace must go in an upward pitch continuously, complete wiring in bedroom closet behind garage, nail plate needed at top plate for cable wires in living room, missing clean out by water closets. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0523-01076
Permit Description: SFR RKM45R T21-M0093 (REVISION 2 Updated Structural cals and pages)
Total Completed Inspections - 23