Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Model Building Permit
Apply Date:
06/08/2023
Applicant:
Amy Stokes, Operations Accountant
Description:
SFR RKM45R T21-M0093 (REVISION 2 Updated Structural cals and pages)

Permit Reviews

Permit Number - TC-MDP-0523-01076
Permit Status: Inspections complete
Permit Description: SFR RKM45R T21-M0093 (REVISION 2 Updated Structural cals and pages)
Start Date Submittal Complete Date Status  
10/30/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 10/30/2023 APPROVED Review Details
06/08/2023 ZZZMODEL PERMIT REVIEW RESIDENTIAL v.1 06/12/2023 APPROVED Review Details

Conditions

Permit Number - TC-MDP-0523-01076
Permit Status: Inspections complete
Permit Description: SFR RKM45R T21-M0093 (REVISION 2 Updated Structural cals and pages)
Date Description Comments
06/10/2023 Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents.
06/08/2023 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
06/08/2023 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
10/30/2023 ISSUED WITH PDEQ CONDITIONS: NO FINAL AND NO CERTIFICATE OF OCCUPANCY UNTIL THE PRIVATE SEWER #P21SD00033 IS ISSUED A DISCHARGE AUTHORIZATION BY PDEQ
06/08/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
10/30/2023 Post-Tension Inspection Report is required.
06/09/2023 A separate building permit for the retaining wall must be issued before finalization of this permit.
05/25/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
06/08/2023 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
06/10/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0523-01076
Permite Description: SFR RKM45R T21-M0093 (REVISION 2 Updated Structural cals and pages)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
10/25/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required support duct register in bathroom, smoke detector in front of laundry must be 3’ away from duct registers, bang plate needed for dryer vent, support gas line in laundry, correctly install bang plate for laundry vent to right of dryer, flu pipe for furnace must go in an upward pitch continuously, complete wiring in bedroom closet behind garage, nail plate needed at top plate for cable wires in living room, missing clean out by water closets.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0523-01076
Permit Description: SFR RKM45R T21-M0093 (REVISION 2 Updated Structural cals and pages)
Total Completed Inspections - 23

Documents

File Name Document Type  
220365 - RINCON KNOLLS LOT 304 - PT REPORT-2023-10-27_V1.PDF DOCUMENTS VIEW
SPAPP-EQ SEWER DA_FINAL-2023-10-27_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
1_APPLICATION_V1.PDF DOCUMENTS VIEW
1_SPECIAL INSPECTION CERT-2023-06-08_V1.PDF DOCUMENTS VIEW
1_SITEPLAN_V1.PDF DOCUMENTS VIEW