Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Model Building Permit
Address:
1814 S POETRY LN
Apply Date:
09/18/2023
Applicant:
Stephanie Bebee
Description:
SFR CVPLAN3 T22-M0044

Permit Reviews

Permit Number - TC-MDP-0523-01055
Permit Status: Complete
Permit Description: SFR CVPLAN3 T22-M0044
Start Date Submittal Complete Date Status  
11/28/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 11/29/2023 APPROVED Review Details
09/19/2023 SITE FROM MODEL PERMIT - PRODUCTION v.1 09/20/2023 APPROVED Review Details

Conditions

Permit Number - TC-MDP-0523-01055
Permit Status: Complete
Permit Description: SFR CVPLAN3 T22-M0044
Date Description Comments
09/19/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
09/20/2023 Post-Tension Inspection Report is required.
05/23/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
09/20/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-0523-01055
Permit Description: SFR CVPLAN3 T22-M0044
Total Completed Inspections - 21
Date Description Inspector Results Comments
10/09/2023 COT - RSPL - Sewer Passed
10/09/2023 COT - RSPL - Rough Soil Passed
10/12/2023 COT - RSEL - Grounding/Bonding Passed
10/12/2023 COT - RSEL - Electrical Underground Passed
10/12/2023 COT - RSBU - Preslab Passed
10/12/2023 COT - RSBU - Excavation/Rebar/Zoning Passed
11/13/2023 COT - RSBU - Exterior Clips/Sheathing Passed Exterior shear wall sheathing is properly nailed off, anchor bolts are installed in load bearing walls with proper plate washers. Okay to proceed with rough-in of other trades and stucco installation.
11/13/2023 COT - RSBU - Roof Nailing Passed Roof sheathing is properly nailed off, H2.5 clips are attached to all exterior wall rafters, TJI joists hangers are properly attached to ledger board and nailed off. Okay to proceed with drying in of roof.
01/17/2024 BULD - Electrical Clearance Passed TEP ECO CLEARANCE ISSUED
02/02/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
02/02/2024 COT - RSPL - Gas Pressure Test Passed
03/04/2024 COT - RSBU - Interior Shear Bracing Passed Drywall for interior shear walls is properly installed and screwed off. Okay to proceed with tape, texture, and paint.
04/26/2024 COT - BULD - SWG Clearance Passed SWG for meter only
05/08/2024 COT - RSEL - Outdoor Lighting Passed
05/08/2024 COT - RSME - Mechanical Final Passed
05/08/2024 COT - RSPL - Yard Water Line Passed
05/08/2024 RSBU - Building Progress Passed
05/09/2024 ENGR Engineering Final Passed
05/10/2024 COT - RSEL - Electrical Final Passed
05/10/2024 COT - RSPL - Plumbing Final Passed
05/10/2024 RSBU - Building Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
PT REPORT LOT 36-2023-11-28_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CBT 36 PP FOR PERMIT_V1.PDF DOCUMENTS VIEW
CBT 36 PT CERT-2023-09-18_V1.PDF DOCUMENTS VIEW