Permit: TC-MDP-0523-01046
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
12752 E LIGHTNING RANCH LN
Address NEW:
12752 E LIGHTNING RANCH LN
Apply Date:
05/15/2023
Applicant:
Amy Stokes, Operations Accountant
Description:
SFR RKK35G T21-M0090
Permit Reviews
Permit Number - TC-MDP-0523-01046
Permit Status: Inspections complete
Permit Description: SFR RKK35G T21-M0090
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/13/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 06/15/2023 | APPROVED |
| 10/23/2023 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 10/24/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0523-01046
Permit Status: Inspections complete
Permit Description: SFR RKK35G T21-M0090
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/15/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-0523-01046
Permit Status: Inspections complete
Permit Description: SFR RKK35G T21-M0090
| Date | Description | Comments |
|---|---|---|
| 06/15/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
| 06/15/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 10/23/2023 | ISSUED WITH PDEQ CONDITIONS: NO FINAL AND NO CERTIFICATE OF OCCUPANCY UNTIL THE PRIVATE SEWER #P21SD00033 IS ISSUED A DISCHARGE AUTHORIZATION BY PDEQ | |
| 06/15/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 10/23/2023 | Post-Tension Inspection Report is required. | |
| 05/18/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 06/15/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0523-01046
Permite Description: SFR RKK35G T21-M0090
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/01/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Partial Pass | 9/1/23: missing king stud and trimmer stud at north bedroom window at each side (will verify at intermediate) |
| 02/13/2024 | RSBU - Building Final | N/A | Re-inspection required | 2/13/23: waiting on engineering final |
| 02/13/2024 | ENGR Engineering Final | N/A | Partial Pass | The back wall on the right hand side, the footer there looks to be damage needs to be repaired |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0523-01046
Permit Description: SFR RKK35G T21-M0090
Total Completed Inspections - 21