Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Model Building Permit
Apply Date:
05/15/2023
Applicant:
Celina Rodriguez
Description:
SFR BT1383-130 T22-M0014

Permit Reviews

Permit Number - TC-MDP-0523-01010
Permit Status: Complete
Permit Description: SFR BT1383-130 T22-M0014
Start Date Submittal Complete Date Status  
05/18/2023 ZZZMODEL PERMIT REVIEW RESIDENTIAL v.1 05/30/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0523-01010
Permit Status: Complete
Permit Description: SFR BT1383-130 T22-M0014
Total Outstanding Activity Conditions - 5
Date Name
05/18/2023 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
05/18/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
05/30/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.
06/15/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
06/15/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.

Conditions

Permit Number - TC-MDP-0523-01010
Permit Status: Complete
Permit Description: SFR BT1383-130 T22-M0014
Date Description Comments
05/11/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-0523-01010
Permit Description: SFR BT1383-130 T22-M0014
Total Completed Inspections - 21
Date Description Inspector Results Comments
06/30/2023 COT - RSPL - Yard Water Line Passed
06/30/2023 COT - RSPL - Sewer Passed
07/03/2023 COT - RSPL - Rough Soil Passed
07/13/2023 COT - RSBU - Preslab Passed
07/13/2023 COT - RSBU - Excavation/Rebar/Zoning Passed
07/13/2023 COT - RSEL - Electrical Underground Passed
07/13/2023 COT - RSEL - Grounding/Bonding Passed
07/31/2023 COT - RSBU - Exterior Clips/Sheathing Passed
07/31/2023 COT - RSBU - Roof Nailing Passed
08/30/2023 COT - RSPL - Gas Pressure Test Passed
09/01/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
09/18/2023 COT - RSBU - Interior Shear Bracing Passed
11/03/2023 BULD - Electrical Clearance Passed 11/3/23: TEP ECO
11/22/2023 COT - BULD - SWG Clearance Passed Approved, SWG Clearance is required for the new service
12/01/2023 COT - RSEL - Electrical Final Passed All construction is complete. Mechanical, electrical, and plumbing fixtures are installed and operational. Electrical panel is properly labeled. Okay to issue Certificate of Occupancy for this permit.
12/01/2023 COT - RSEL - Outdoor Lighting Passed Porch lights match plan specifications.
12/01/2023 COT - RSME - Mechanical Final Passed All construction is complete. Mechanical, electrical, and plumbing fixtures are installed and operational. Electrical panel is properly labeled. Okay to issue Certificate of Occupancy for this permit.
12/01/2023 COT - RSPL - Plumbing Final Passed All construction is complete. Mechanical, electrical, and plumbing fixtures are installed and operational. Electrical panel is properly labeled. Okay to issue Certificate of Occupancy for this permit.
12/01/2023 RSBU - Building Final Passed All construction is complete. Mechanical, electrical, and plumbing fixtures are installed and operational. Electrical panel is properly labeled. Okay to issue Certificate of Occupancy for this permit.
12/01/2023 RSBU - Building Progress Passed
12/01/2023 ENGR Engineering Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
BELLA TIERRA - LOT 10 START_V1.PDF DOCUMENTS VIEW
BELLA TIERRA II 10 SIC-2023-05-15_V1.PDF DOCUMENTS VIEW