Permit: TC-MDP-0426-00207
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
488 N COVILLE DR
Address NEW:
488 N COVILLE DR
Apply Date:
08/20/2026
Applicant:
Celina Rodriguez
Description:
Enclaves at Tumamoc 1442 Plan (Model Master Plan TC-MDP-1225-00792)
Permit Reviews
Permit Number - TC-MDP-0426-00207
Permit Status: Inspections
Permit Description: Enclaves at Tumamoc 1442 Plan (Model Master Plan TC-MDP-1225-00792)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/26/2026 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 09/02/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0426-00207
Permit Status: Inspections
Permit Description: Enclaves at Tumamoc 1442 Plan (Model Master Plan TC-MDP-1225-00792)
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 04/01/2026 | Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. |
| 04/01/2026 | MANUAL J |
| 04/01/2026 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 09/02/2026 | Prior to Final - Required Documents - Post-Installed Anchor Inspection Report is required. |
Conditions
Permit Number - TC-MDP-0426-00207
Permit Status: Inspections
Permit Description: Enclaves at Tumamoc 1442 Plan (Model Master Plan TC-MDP-1225-00792)
| Date | Description | Comments |
|---|---|---|
| 04/01/2026 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 04/01/2026 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0426-00207
Permite Description: Enclaves at Tumamoc 1442 Plan (Model Master Plan TC-MDP-1225-00792)
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/29/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 09/29/2026 Add anchor bolts at marked locations, add A34 clip to outside rafters at side porch, add straps to GLU beam post connection, detail 203 at SW13 calls for 2x6s 24"o.c., add clips to bottom of stair stringers, add anchor bolts and 3x3" steel washer to front garage shear wall at sill plates, add roof nails to loose panel as marked. |
| 09/29/2026 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 09/29/2026 Add anchor bolts at marked locations, add A34 clip to outside rafters at side porch, add straps to GLU beam post connection, detail 203 at SW13 calls for 2x6s 24"o.c., add clips to bottom of stair stringers, add anchor bolts and 3x3" steel washer to front garage shear wall at sill plates, add roof nails to loose panel as marked. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0426-00207
Permit Description: Enclaves at Tumamoc 1442 Plan (Model Master Plan TC-MDP-1225-00792)
Total Completed Inspections - 11
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/11/2026 | COT - RSPL - Yard Water Line | Passed | ||
| 09/11/2026 | COT - RSPL - Sewer | Passed | ||
| 09/11/2026 | COT - RSPL - Rough Soil | Passed | ||
| 09/21/2026 | COT - RSBU - Preslab | Passed | 09/21/2026 Corrections made. Okay for concrete placement. |
|
| 09/21/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 09/21/2026 Corrections made. |
|
| 09/30/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 9/30/2026 Corrections made. |
|
| 09/30/2026 | COT - RSBU - Roof Nailing | Passed | 9/30/2026 Corrections made. |
|
| 10/12/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Passed | |
| 10/12/2026 | COT - RSPL - Gas Pressure Test | Passed | Passed | |
| 10/12/2026 | BULD - Electrical Clearance | Passed | Passed | |
| 10/23/2026 | COT - RSBU - Interior Shear Bracing | Passed |