Permit: TC-MDP-0426-00199
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
325 N COVILLE DR
Address NEW:
325 N COVILLE DR
Apply Date:
07/17/2026
Applicant:
Celina Rodriguez
Description:
Enclaves at Tumamoc 1765 Plan (Model Master Plan TC-MDP-1225-00794)
Permit Reviews
Permit Number - TC-MDP-0426-00199
Permit Status: Inspections
Permit Description: Enclaves at Tumamoc 1765 Plan (Model Master Plan TC-MDP-1225-00794)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/20/2026 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 07/28/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0426-00199
Permit Status: Inspections
Permit Description: Enclaves at Tumamoc 1765 Plan (Model Master Plan TC-MDP-1225-00794)
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 04/01/2026 | Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. |
| 04/01/2026 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 07/24/2026 | Prior to Final - Required Documents - Post-Installed Anchor Inspection Report is required. |
Conditions
Permit Number - TC-MDP-0426-00199
Permit Status: Inspections
Permit Description: Enclaves at Tumamoc 1765 Plan (Model Master Plan TC-MDP-1225-00794)
| Date | Description | Comments |
|---|---|---|
| 04/01/2026 | MANUAL J | |
| 04/01/2026 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 04/01/2026 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0426-00199
Permite Description: Enclaves at Tumamoc 1765 Plan (Model Master Plan TC-MDP-1225-00794)
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/21/2026 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Not Ready | Remove all loose fill from footings. Provide a minimum 12" depth at all perimeters including garage area. 10/21/2026 |
| 10/21/2026 | COT - RSBU - Preslab | N/A | Not Ready | Remove all loose fill from footings. Provide a minimum 12" depth at all perimeters including garage area. 10/21/2026 |
| 10/21/2026 | COT - RSEL - Electrical Underground | N/A | Partial Pass | Partial pass. Pending connection to equipment. 10/21/2026 |
| 10/28/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 10/28/2026 Nails missing at top plate splice upstairs as marked, add 12 nails each side of splice on face of plate. Loose shear panel needs nails as marked. Add anchor bolts at marked locations. Add strap to beam/post connection at side patio. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0426-00199
Permit Description: Enclaves at Tumamoc 1765 Plan (Model Master Plan TC-MDP-1225-00794)
Total Completed Inspections - 8
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/14/2026 | COT - RSPL - Rough Soil | Passed | Okay to backfill. Shading required. 10/14/2026 | |
| 10/14/2026 | COT - RSPL - Sewer | Passed | Okay to backfill. Shading required. 10/14/2026 | |
| 10/14/2026 | COT - RSPL - Yard Water Line | Passed | ||
| 10/23/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 10/23/2026 | COT - RSBU - Preslab | Passed | 10/23/2026 Corrections made. Okay for concrete placement. |
|
| 10/23/2026 | COT - RSEL - Electrical Underground | Passed | ||
| 10/28/2026 | COT - RSBU - Roof Nailing | Passed | ||
| 10/30/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 10/30/2026 Corrections made, walked rest of structure. |